1. Remove the Guard and Cap
WARNING: Risk of personal injury.
Supply lines may be
pressurized. Do not lean over the diverter body while turning or
removing the guard or cap.
Make sure that the valves are closed. (Cold = fully
counterclockwise; hot = fully clockwise.)
Turn off the main water supply.
Wrap a rag around the cap to prevent water spray.
IMPORTANT!
Water may spray from the diverter body when you
remove the cap.
Carefully remove the cap.
Discard the guard and cap.
Cap
Guard
Diverter Body
Close Hot
Close Cold
Kohler Co.
3
1049620-2-B
Summary of Contents for K-T387
Page 23: ...1049620 2 B ...