2. Prepare the Site
The PDS is designed to fit within a service closet or 2x6 stud
cavity with access panel. The service closet or access panel must
be located less than 30 ft (9.14 m) from the overhead rain panel.
Recommended maximum distance is 25 ft (7.62 m).
If mounting boards are required, they should be positioned to
allow adequate surface area to attach the PDS via the existing
mounting holes on both ends of the PDS box.
Install a 120 V GFCI/RCD electrical outlet within the service
closet or 2x6 stud framing, within 24” (61 cm) of the PDS. Locate
the outlet in close proximity to the PDS to allow enough cable to
create a drip loop.
Note:
For hardwire installations, order Service Kit #1078031.
Outlet
Drip Loop
2x6
Position
to far left.
Power Data Supply
Mounting Board
8-1/4" (21 cm)
2x6 Stud Cavity
6" (15.2 cm) Min
1078520-2-A
8
Kohler Co.