Bath Operation (Cont.)

C.  Air System Operation

¨

  Slide the sliding slip to unlock the panel. Touch the power button on the user keypad “ 

 “ 

¨

  Observe that the blower motor starts.

¨

  Observe that air is blowing through all of the airjets. 

¨

  Slide in “ 

 “ direction. 

¨

  Verify that the air flow increases. 

¨

  Slide in “ 

 “ direction. 

¨

  Verify that the air flow decreases. 

¨

  Touch the power pump on/off “ 

 “ on the keypad to stop the blower motor.

D.  Manual Purge Operation

¨

  Drain the bath.

¨

  When the bath has drained, slide the sliding slip to unlock the panel, touch the purge button once “

 

 

“ .

¨

  Observe that the blower motor starts.

¨

  Observe that water comes out of the airjets.

¨

  Verify that touching the purge button “

 

 

“ again stops the blower motor. If the purge button is not touched, 

the cleaning will automatically stop after 2 minutes.

E.  Automatic Purge Operation

¨

  Fill the bath with at least 20cm water.

¨

  Slide the sliding slip to unlock the panel. Touch pump on/off “ 

 “.

¨

  1 minute after pump starts, slide the sliding slip to unlock the panel, touch pump on/off “ 

 “ again, the 

pump stops.

¨

  Slide the sliding slip to unlock the panel. Touch electronic drain on/off “

 

 

“ , waiting for water drain.

¨

  Observe that the blower motor starts and stops automatically after about two minutes.

F.  Power Off Compelling Drain Protect Function

¨

  Slide the sliding slip to unlock the panel. Touch electronic drain on/off “

 

 

“ , the electronic drain stops.

¨

  Unplug the connector plugs of the controller.

¨

  Observe that the electronic drain starts automatically.

¨

  Plug again, the electronic drain restores its former status.

NOTE:

 Please do not use the bath in case of outage. In this case, the electronic drain automatically opens and the 

bath can not be filled with water.

G.  Test of the Overflow Function

¨

  Slide the sliding slip to unlock the panel. Touch the electronic drain on/off button “

 

 

“ to close the drain.

¨

  The bath is filled until the drain automatically starts and cellular sound alarm is heard. Meanwhile, the green 

light of “

 

 

“ flashes.

¨

  Turn off the tap, water level will drop to the overflow level and the drain will stop automatically. Meanwhile, 

the “

 

 

“ is pink. (The overflow level differs for each bath. Please refer to “Roughing-in”).

NOTE:

  When  the  bath  reaches  overflow  level,  water  level  may  rise  quickly  if  you  enter  the  bath  or  start 

the  bubble  massage  function,  which  may  trigger  the  compelling  drain  function.  Compelling  drain  function 

 

will discharge lots of water, so it is not recommended to use the bath when it reaches overflow level.

H.  Compelling Drain Function

¨

  If  the  overflow  level  sensor  does  not  work,  you  can  use  the  compelling  drain  function  to  prevent  water 

overflow to your bathroom. Please refer to the automatic drain water level in the Roughing-in.

Summary of Contents for K-45600X

Page 1: ...Installation and Care Guide BubbleMassage Bath 1198675 X2 A 2013 Kohler Co K 45600X K 45602X K 45604X...

Page 2: ...CCESS NO WARRANTY SERVICE Ventilation must be provided to access panel in order to allow heat from blower to dissipate Jalousie window access is recommended Thank you for choosing Kohler Kohler crafts...

Page 3: ...ct Requirements WARNING Keep the area around the blower motor clean and free of debris Ensure that the area around the blower motor is free of sawdust insulation dirt or other small loose debris Such...

Page 4: ...er than 2 5 cm from the wall or other objects Make sure the flooring offers adequate support for your bath and verify that the subfloor is flat and level Make sure the deck is adequately supported Ins...

Page 5: ...as been factory tested and approved When removing bath from protective carton DO NOT LIFT BATH BY PIPE WORK Inspect for any possible damage that may have occurred in transit Position a clean drop clot...

Page 6: ...in the air harness are secure Verify that the blower motor is secure Temporarily remove the plastic drop cloth or other protective sheeting from the bath Slide the sliding slip to unlock the panel To...

Page 7: ...dations NOTE Please read these steps carefully before you operate your bath with airjets Troubleshoot any problems using the Troubleshooting section NOTE Please do not use the bath in case of outage I...

Page 8: ...ouch again to stop it blue light half flashes Touch the button The blower motor will automatically stop after running for about 20 minutes Bubble Adjustment Slide the sliding slip to unlock the panel...

Page 9: ...Off No Display 2 Power On 4 Blower Open 3 Light Change to Stand by Situation Blue Orange Red Orange Green Blue White Blue 50 Blue White Pink Water Temperature Light depend on water temperature Water T...

Page 10: ...1198675 X2 A 10 Kohler Co Bath Operation Cont 38 c o 38 c o 38 c o 5 Drain Open 7 System Clean 6 Overflow Alarm Green 50 Blue White 50 Blue 50 Blue White White Orange Green Flash...

Page 11: ...ff Compelling Drain Protect Function Slide the sliding slip to unlock the panel Touch electronic drain on off the electronic drain stops Unplug the connector plugs of the controller Observe that the e...

Page 12: ...lace user keypad 6 Blower motor operates but speed timing does not work A User keypad cable loose or dam aged A Check wire connections If necessary replace user keypad B User keypad does not work B Re...

Page 13: ...because of excessive moisture Cleaning Surfaces Do not use abrasive cleansers on any surfaces as they will scratch and dull the surface Wipe out the bath after each use to prevent a build up of soap...

Page 14: ...GFCI ELCB 1198675 X2 A 14 Kohler Co...

Page 15: ...Kohler Co 15 1198675 X2 A GFCI ELCB 220 240 10 50...

Page 16: ...1198675 X2 A 16 Kohler Co 1 390 5 15 0 4 2 5 2 2...

Page 17: ...Kohler Co 17 1198675 X2 A drywall 50 2...

Page 18: ...1198675 X2 A 18 Kohler Co GFCI ELCB GFCI ELCB 220 10 10 38 c o...

Page 19: ...Kohler Co 19 1198675 X2 A 600 12 6 x 1800 12 x 900...

Page 20: ...1198675 X2 A 20 Kohler Co 38 c o 1 3 30 1 20 2 20 2...

Page 21: ...Kohler Co 21 1198675 X2 A 38 c o 38 c o 38 c o 38 c o 1 2 4 3 50...

Page 22: ...1198675 X2 A 22 Kohler Co 38 c o 38 c o 38 c o 5 7 6 50 50 50...

Page 23: ...Kohler Co 23 1198675 X2 A 2 20 1 2...

Page 24: ...1198675 X2 A 24 Kohler Co 1 GFCI ELCB 2 3 20 GFCI ELCB GFCI ELCB 4 20 5 6 7...

Page 25: ...Kohler Co 25 1198675 X2 A 8 9 10 11 12 13 1 mirror glaze 28 metal polish Green Oil...

Page 26: ...1198675 X2 A 26 Kohler Co 10 60 Soda Acid...

Page 27: ...Kohler Co 27 1198675 X2 A...

Page 28: ...2046224 E mail callcenterthailand kohler com KOHLER THAILAND PUBLIC COMPANY LIMITED 16th FL JasmineCityBldg 2 Soi Sukhumvit23 Sukhumvit Road Wattana Bangkok10110Thailand Call Center Tel 66 2204 6222 F...

Reviews: