background image

-3-

TO REMOVE EXISTING TOILET

Turn off the water supply. Flush the toilet, and use a sponge
to remove the remaining water from the tank and bowl.
Disconnect the supply shut-off valve (if present), and remove
the old tank and bowl.

(

)

INSTALLATION

Fig.#2

2

Remove the old gasket from the floor
and the closet flange with a putty knife.
Remove the old T-bolts and discard
them.

if the new toilet is not

installed immediately, temporarily stuff
a rag into the closet flange.

NOTICE:

T

NOTICE:

Do not use white cement or high lime content

cements to install this toilet. The expansion of cement due to
a rise in temperature may make the toilet crack or cause
damage. Kohler is not responsible for any damage caused by
installation with the use of cement.

Closet Flange

mm

67mm;

200mm
160

Fig.#3

3

TO INSTALL SUPPLY
SHUT-OFF VALVE

Install the supply shut-off valve so it is
200mm above the finished floor line,
and 160mm to the left of the closet
flange centerline.

The centerline of the supply shut-off
valve outlet should extend 67mm from
the finished wall. Install the supply
shut-off valve with the outlet vertical.

Supply Shut-Off Valve

Closet Flange
Centerline

160

305/400

200

10mm

5

TO INSTALL BOWL

Position the template and align with
drain hole.

Mark down the position of foot and 5
holes.

Drill holes on ground with the drill of
10mm (3/8"), then insert anchor to
holes.

CAUTION:

Please make sure there is

no water pipe or spool under the 5
holes to be drilled.

Fig.#4

4

Fig.#5

5

Drain Hole

3/8

10mm

1446150-T01-B

Summary of Contents for K-30215T-S

Page 1: ...Seat COMPACT K 27350T REACH COMPACT Skirted 1PC 305mm W O Seat K 30215T S REACH COMPACT Skirted 1PC 400mm W O Seat K 30216T S Recommended Toilet Seat Toilet Seat COMPACT K 27349T Quiet Close Toilet Se...

Page 2: ...ING Risk of external leakage Handle vitreous china products very carefully Vitreous china can break and chip if you overtighten bolts and nuts The fill valve nut has been factory tightened to design s...

Page 3: ...ge Kohler is not responsible for any damage caused by installation with the use of cement Closet Flange mm 67mm 200mm 160 Fig 3 3 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so...

Page 4: ...astic to ground and mounted with 3 set of bolts firmly not supplied 3 NOTE Must use the toilet installation gasket ring not supplied to seal the area where the waste pipe contacts the construction sec...

Page 5: ...d rust from the system Make sure water supply is off Remove valve END by rotating it 1 8 turn counterclockwise While holding a container over the uncapped VALVE to prevent splashing turn water supply...

Page 6: ...tions Screw Snap SCALE 5 1 OPEN CLOSE To elevate water level Rotate screw clockwise and raise float to the desired water level Elevate water cup to a proper position as well Refer to float adjustment...

Page 7: ...iston seat washer assembly D Remove the tank and tighten the flush valve nut if flush valve gasket is leaking Do not overtighten If leakage continues replace the gasket E Adjust the tank water level i...

Page 8: ...It is recommended to use Continuous Clean Assembly for the cleaning of tank and protection of valves Do not use corrosive in tank cleaners Products containing chlorine calcium hypochlorite can seriou...

Reviews: