BEFORE YOU BEGIN

BEFORE YOU BEGIN

ALBERRY

INSTALLATION INSTRUCTIONS

K-2463

CABINET 30

T

"

ORDERING INFORMATION

This installation covers the following products in the
range of ALBERRY

ALBERRY CABINET.............................................K-2463T

...........................................................K-2463T

SAFETY: WARNINGS

Kohler products are precision-engineered and should give
continued superior and safe performance, provided:

1. They are installed, commissioned, operated and

maintained in accordance with the recommendations given
in this Manual.

2. Periodic attention is given, as necessary, to maintain the

product in good functional order. Recommended
guidelines are given in the

section.

Carefully inspect the new fixture for any signs of damage.

When installing Kohler Products, manufacturers guidelines for
power tool safety should be followed.

MAINTENANCE

1.

2.

·

·

·

·

·

·

·

·

·

·

Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
Ensure all electric work has completed before furniture
installation.
Make sure the finished wall is straight and plumb, and the
floor is flat and perendicular to the finished wall.
Remove any moldings that may inhibit the vanity from
being flush against the finished wall.
It is recommended that the drawer, door(s), and shelf be
removed from the cabinet before beginning the cabinet
installation. Doing so will ease the installation process.
Refer to the sections contained in this guide for proper
removal.
ALBERRY cabinet mainly adopts birch wood and partially
high quality E1 grade artificial board . Its harmful gas
emission is less than 1.5mg/L.
Turn off the water supply.
The plumbing installation must comply with Water Supply
Regulations/Bye-laws, Building Regulations or any
particular regulations and practices, specified by the local
water company or water undertakers. The installation
should be carried out by a plumber.
Before installation carefully inspect the new fixture for any
signs of damage.

·

·

·

·

·

·

·

·

·

·

E1

1.5

mg/L

(

)

158

200436

1093419-T01-B

Summary of Contents for K-2463

Page 1: ... and safety instructions All information in these instructions is based upon the latest product information available at the time of publication Kohler China reserves the right to make changes in product characteristics packaging or availability at any time without notice Ensure all electric work has completed before furniture installation Make sure the finished wall is straight and plumb and the ...

Page 2: ...D MATERIALS Pencil Measuring Tape Level Miter Box Safety Glasses Drill Screwdrivers Hole Saw 63 630 63 531 762 531 851 265 580 6 Kohler reserves the right to change marked dimensions without prior notice Reference Value 1093419 T01 B ...

Page 3: ...re a watertight seal exisits on all washbasin drain connections Provide access to the plumbing connections for future plumbing maintenance The hot and cold water supplies must be installed with isolating valves Caution Caution Note A H C P B Preparation 1 cabinet body Pull out cabinet body from carton 2 Feet Take out accessory pack and fit feet to base B 1 2 3 Door Panel left DoorPanel right Activ...

Page 4: ...er and adjust it to desired height C Door Attach 1 Line up pin with cup 2 Snap latch into base 3 Repeat for remaining hinge 4 C 1 2 3 Latch Bracket Pin Fig 3 3 Fig 4 4 Release 1 Hold door with hand 2 Release latch from bracket 3 Repeat for remaining hinge 1 2 3 Bracket Latch Fig 5 5 1093419 T01 B ...

Page 5: ...oles 2 Secure with screws 3 Attach door to hinge D 1 2 1 2 3 Top of Door Vanity Locking Screw Locking Screw Fig 7 7 Adjust 1 Adjust screws of each hinge 2 Adjust the door in height direction and depth direction Note to adjust screws only corresponding to its direction 1 2 Fig 6 6 Height Depth 1093419 T01 B ...

Page 6: ...ealant to the top of sidebo rd of washbasin cabinet and position the cabinet board with pre opened washbasin hole on the cabinet a E 1 Fig 8 8 1 2 2 Apply some sealant equably to the installing part and position the washbasin in the cabinet board 2 Fig 9 9 1 2 1093419 T01 B ...

Page 7: ...der the cabinet board with bolts Caution 1 2 Sealant Clamp Clamp Note Do not tighten the bolts completely at the first time Adjust the washbasin position to the center of the pre opened hole and tighten the bolts completely 3 Apply some sealant equably as bead to the washbasin edge tangent to cabinet board 3 Fig 11 11 Fixed Cabinet Board 1 Use cabinet board linkers to connect the cabinet board and...

Page 8: ... 1 P Connect Drainage 1 Inwall drainage P Trap Please install the drain assembly and faucet as shown Please set the water supply and drainage position according to the suppliers instructions You can adjust the height of shelf to fit the drain assembly 1093419 T01 B ...

Page 9: ...d performance even in bathroom of huge humidity Yet do not splash and pour water directly on the bathroom cabinet Make sure that the bathroom is not over damp and wipe any splashes from surfaces immediately 4 Maintenance of door board Clean and wipe door board regularly and wipe the condensation vapor with dry and soft cloth 5 Ensure that electrical connections for appliances such as head lamp is ...