2. Fix the power cord to the bathroom heater

(1) Remove the screw on the wiring cover plate.
(2) Open the wiring cover plate.
(3) Lift the terminal protection cover.
(4) Loosen the screw fixing the power cord clip.
(5) Loosen the screw on the wiring terminal, insert the

power cord (not supplied) connected to the indoor fixed
line into the wiring terminal, tighten the wring terminal
screw.

(6) Fix the power cord with power cord clips. (The power

cord clip must pin the insulation sheath of power cord.)

(7) Use the screw removed in step (1) to fix the wiring

cover plate again.

2.

(1)
(2)
(3)
(4)
(5)

(

)

(6)

(

)

(7)

(1)

Power Cord

N

L

Wiring Terminal

3. Installing the Main Body Method 1 integrated ceiling.

integrated ceiling should be 300*300, 300*450, 300*600

(1) Disassembly the decorated plate around the position of

the product installation.

3.

300*300

300*450

300*600

(1)

(

)

300mm*300mm integrated ceiling

300mm*300mm

Disassembly 6 pieces

6

Disassembly 6 pieces

6

300mm*450mm integrated ceiling

300mm*450mm

300mm*600mm integrated ceiling

300mm*600mm

Disassembly 3 pieces

3

-6-

(2) Bend the installation template to 90 at the bending line.

Push the template to the location of fixed hole A in the
ceiling as the diagram shows.

°

(2)

90

A

(

)

300mm*300mm integrated ceiling

300mm*300mm

Bending Line

Install Template

Install Template

Install Template

Install Template

Install Template

Install Template

Cement Board

Cement Board

Ceiling

Drill Position

Fixed Hole A

A

Drill Position

600

580

200

300

Bottom View

Bottom View

1374351-T01-A

Summary of Contents for K-24619T-0

Page 1: ...allation and Homeowners Guide Veil Bathroom Heater S600P S600P K 24619T 0 KOHLER CHINA INVESTMENT CO LTD NO 158 JIANG CHANG SAN ROAD JING AN DISTRICT SHANGHAI PRC POST CODE 200436 158 200436 1374351 T...

Page 2: ...7 2008 GB7000 1 GB7000 202 and GB T17743 please leave instructions for the consumer GB 4706 1 2005 GB4706 23 2007 GB 4706 27 2008 GB7000 1 GB7000 202 GB T17743 WARNING Risk of electrical shock WARNING...

Page 3: ...rew BTP4 8 BTP4 8 Tri Self Tapping Screw BTP4 8 Expansion Pipe M6 Screw Rod M6 M6 Butterfly Nut M6 Keel M6 Screw Nut M6 6 Cushion 6 6 Washer 6 Air Outlet Window Clamp Air Exhaust Pipe Ventilation Outl...

Page 4: ...3 10 PREPARATIONS BEFORE INSTALLATION A Preparation before the installation A 1 Open the hole of outlet window Make sure that the outlet window s position it should be lower than the outlet of the bat...

Page 5: ...ipe 10 M6 Screw Rod M6 1285553 Lock Assy M6 Butterfly Nut M6 6 Washer 6 6Spring Washer 6 M6 Nut M6 Note Initial Length 150mm Stretch Length 2200mm 150mm 2200mm 305mm C Packing List C Remote Control 13...

Page 6: ...have enough length for the installation The distance between the product and the air outlet window shall be 2000mm or lower Cut the screw rod M6 to suit the distance between the ceiling and the roof...

Page 7: ...od 1 integrated ceiling integrated ceiling should be 300 300 300 450 300 600 1 Disassembly the decorated plate around the position of the product installation 3 300 300 300 450 300 600 1 300mm 300mm i...

Page 8: ...nder by 8 BTP4 8 screw 3 M6 4 8 BTP4 8 M6 Butterfly Nut M6 6 Washer 6 6 Spring Washer 6 M6 Nut M6 M6 Nut M6 BTP4 8 Triangular Self Tapping Screw BTP4 8 8 Suspender Cement Board Ceiling Surface Install...

Page 9: ...ors Indoors Slant Taper 1 100 1 50 BTP4 8 Triangular Self Tapping Screw BTP4 8 1 Ventilation Outlet Assy Ventilation Outlet Assy Clamp Air Exhaust Pipe 7 Install the decorated plate and adjust the nut...

Page 10: ...the ceiling 2 B Cement Board Suspender 9 2 Fix the ventilation outlet assy to the main body using the BTP4 8 self tapping screw 3 Fix the suspension bracket to the main body using the 8 BTP4 8 self t...

Page 11: ...Choose a mounting location for the remote holder Drilling two holes with depth larger than 45mm on the wall by drill with a diameter of 6mm in accordance with the position of screw holes on the remote...

Page 12: ...can be heard and the LED light is on it means paring is successful B 3 LED C Button Function C DOWN Timer Down Temperature Down Brightness Down UP Timer Up Temperature ON Brightness Up HEATER Turn on...

Page 13: ...o the default after each use HEATER the default time is 3 hours minimum time is 30 minutes and maximum time is 6 hours If press Stop when the heater is working the heater will continue to work for nex...

Page 14: ...ersely B The remote controller is used in an inappropriate position or angle C Circuit breaker is in the Off position C No wake up C Low battery A Wait until the power is restored A Please replace the...

Page 15: ...r supply corresponding protective measures should be taken 2 Please confirm no water penetration at the connection area of AC wire and the connection area is not easy to be affected by damp 3 The head...

Reviews: