background image

-8-

Cleaning

Caution! Risk of product damage.

Caution! Risk of product damage.

Caution! Do not use in-tank cleaners.

Many cleaners

contain abrasive and chemical substances, and should
not be used for cleaning stainless steel, enamel,
plated or plastic fittings. These finishes should be
cleaned using a mild washing up detergent or soap
solution, rinsed and then wiped dry with a soft clean
cloth.

Most toilet bowl

cleaners are not harmful to the vitreous china surface
of the toilet bowl. Please follow the bowl cleaner
manufacturer

,

s instructions carefully.

Products

containing chlorine (calcium hypochlorite) can
seriously damage fittings in the tank. This damage can
cause leakage and property damage.

CAUTION: Don t use any cement while installing
the toilet.

WARNING: Risk of product damage.

Heat expansion of the toilet may damage

the feet of the toilet. Kohler will not be responsible for
any damage because of using cement.

Do not throw into the toilet what is easy to block it,
such as newspaper, paper pilch, sanitary towel.
Do not bump the vitreous china with great force to
prevent it from damaging and leaking.
Do not use the product in the water below 0 C.

o

'

Please do not use hard materials (like

scouring pad) to clean product surface, especially the
product logo.

CAUTION:

0 C

o

USER MAINTENANCE

USER MAINTENANCE

1332802-T01-E

Summary of Contents for K-20168T-SL-CG1

Page 1: ...istics packaging or availability at any time without notice These instructions contain important care cleaning and warranty information please leave instructions for the consumer ASME A112 19 2 2018 Q...

Page 2: ...or Optional Wall Installation 1036901 VEIL FS Toilet W Soft Close Seat K 21297K S Includes VEIL FS Toilet Bowl K 20706K Includes Saile QC Toilet Seat Hidden Hinge Base K 4141T Includes P Trap for Opti...

Page 3: ...rap for Optional Wall Installation 1036901 VEIL WF Toilet W SL Beam SR D BN 3 4 5 K 23097T BNSL Includes VEIL Wall Face Pan BEAM SR DC BN K 23099T DNSL Includes REACH Slim Quiet Close Toilet Seat K 77...

Page 4: ...signs of damage When installing Kohler Products manufacturers guidelines for power tool safety should be followed MAINTENANCE 1 2 TOOLS AND MATERIALS REQUIRED Not supplied 254mm 10 adjustable wrench...

Page 5: ...Recommended inlet connections are 3 8 BSP 5 INSTALLATION Install Flushing Mechanism 1 Install The Tank 1 Turn the water supply off before installing the new toilet 2 Install the concealed tank system...

Page 6: ...wall Make sure that you avoid hidden cables and pipes when drilling holes in the floor or wall Caution 2 1 2 4 3 3 15 38 3 Remove the bowl and place the installation template on the floor Drill the a...

Page 7: ...th hex wrench Making sure that they install correctly in the holes in the floor It is suggested to use other auxillary light such as torch to eluminate one preserved installation hole of the toilet Wa...

Page 8: ...containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage CAUTION Don t use any cement while installing the toilet WARNING Ri...

Page 9: ...into walls check there are no hidden electrical wires cables or water supply pipes with the aid of ar electronic detector If you use power tools do not forget 1 Wear eye protection 2 Unplug equipment...

Page 10: ...horizontal distance between the bottom of plate and the surface of squat pan is advised to be 1200mm and the horizontal distance between the bottom of plate and toilet cover is advised to be 600mm De...

Page 11: ...rench as shown in Fig 5 Process inlet pipe thread and fix inlet pipe connector Put seal onto the nut Tighten valve assembly and inlet connector with wrench Put nut and seal onto outlet pipe Tighten va...

Page 12: ...n the nut to avoid deforming or damaging the bottom board Test run and check the valve after installation Water continues running at flush valve Check whether the rod is still too long Continue press...

Page 13: ...Pull Snap 8 7 8 Maintenance Test run and check the valve after installation Leakage at inlet connector Refer to Fig 7 to check whether the seal is properly installed nut is tightened and whether the...

Reviews: