background image

VEIL

INSTALLATION INSTRUCTIONS

SKIRTED 1PC LIGHTING

(

)

S-TRAP 305mm K-1381T-XTS
S-TRAP 400mm K-1382T-XTS

-1-

·

·

·

Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
warranty information -

.

please leave instructions for the

consumer

·

·

·

-

NOTES

·

·

·

·

·

·

·

·

·

Observe all local plumbing and building codes.
Shut off the water supply.
Seat post holes are on 140mm (5-1/2") centers.
Ensure that the new drain has the correct roughing-in
dimension. This toilet has a 305mm /400mm roughing-in
dimension.

.

Closet flange must be 305mm/400mm on-center from wall.
Carefully inspect the new fixture for any sign of damage.
For new construction, refer to the dimensions in

for locating the shut-off valve.

Fixture dimensions are nominal and conform to tolerances
established by ASME Standards (A112.19.2-2018).

See Fig. #1

Fig. #1

and Fig. #3

This product complies with Q/KCI-006-2018.

·

·

·

·

·

·

·

·

·

140mm

305mm/400mm(

1)

305mm/400mm

1

3

ASME

A112.19.2-

2018.

Q/KCI-006-2018

(

)305mm........K-1381T-XTS

...........................................K-77070T

(

)400mm........K-1382T-XTS

...........................................K-77070T

ORDERING INFORMATION

Includes

VEIL

400mm .....................K-1382T-XTS

Includes Elongated Slim Seat ................................K-77070T

VEIL Skirted 1PC Lighting 305mm .....................K-1381T-XTS

Elongated Slim Seat ...............................K-77070T

Skirted 1PC Lighting

©

©

Copyright Kohler China Investment Co., Ltd. 2019

2019

WARNING: Risk of personal injury or product
damage

WARNING: Risk of external leakage

: Handle vitreous china products very carefully.

Vitreous china can break and chip if you overtighten
bolts and nuts.

. The fill valve

nut has been factory-tightened to design specifications.
If re-tightening is required, wrench tighten one turn
past finger tight .

No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC

POST CODE 528137

2

528137

8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA

256410

8

256410

NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC

110400

1

110400

:

POST CODE:

POST CODE:

1371050-T01-A

Summary of Contents for K-1381T-XTS

Page 1: ... sign of damage For new construction refer to the dimensions in for locating the shut off valve Fixture dimensions are nominal and conform to tolerances established by ASME Standards A112 19 2 2018 See Fig 1 Fig 1 and Fig 3 This product complies with Q KCI 006 2018 140mm 305mm 400mm 1 305mm 400mm 1 3 ASME A112 19 2 2018 Q KCI 006 2018 305mm K 1381T XTS K 77070T 400mm K 1382T XTS K 77070T ORDERING ...

Page 2: ...y shut off valve below the tank install one before installing the new toilet NOTICE 254mm 305mm 8mm T 2 10mm Fig 1 1 Unit mm Kohler reserves the right to change marked dimensions without prior notice Reference Value Finished Wall 305 400 393 725 387 280 320 375 225 311 311 692 200 190 TO REMOVE EXISTING TOILET Turn off the water supply Flush the toilet and use a sponge to remove the remaining wate...

Page 3: ...3 3 Fig 4 4 Fig 5 5 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 200mm above the finished floor line and 190mm to the left of the closet flange centerline The centerline of the supply shut off valve outlet should extend 67mm from the finished wall Install the supply shut off valve with the outlet vertical Supply Shut Off Valve Closet Flange Centerline 190 305 200 10m...

Page 4: ...et NOTE 1 NOTE 2 o Install plastic to ground and mounted with 3 set of bolts not supplied firmly Carefully align and lower the bowl Apply weight to the bowl rim to let the outlet insert into plastic trap Carefully thread the screws into the brackets until toilet is secure Alternately tighten left and right sides to prevent pulling the toilet off center Install cap to cover screw Do not overtighten...

Page 5: ...the marked water line 1 8 1 8 TO CONNECT WATER SUPPLY Flexible hose not provided are recommended to connect the supply line to the fill valve If you use a rigid connection not provided take care not to apply side forces to the bottom of the fill valve Be sure the rigid connection must be fit with supply line completely to prevent damage shank by forced connection Supply Shank Supply Shut Off Valve...

Page 6: ...e continues to run allowing water to enter tank 3 Incorrect water level height FILL FLOAT WITH BALLAST Adjust the float by the cross shaped thread and sliding it up or down on the float rod until the water level is at the marked water line Test flush the toilet Check all connections for leakage for several days Set the tank cover in place on the tank Fig 15 15 A Foreign particles lodged under the ...

Page 7: ...1 A B A B A B C D E A 1 8 1 8 B C D E 2 3 A B A B 4 A 2A A 5 A B C D A B C D 6 A B A B 7 1371050 T01 A ...

Page 8: ... cleaners or solvents Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage 0 C o ...