1. Install the Control
Use lag screws or other suitable fasteners (not provided) to secure
the wall bracket to a reinforced section of the wall. Refer to the
roughing-in information packed with the product.
Position the hot and cold water supplies according to the
roughing-in information packed with the product.
Apply thread sealant to the threads of the supply pipes, and
install the supply pipes to the hot and cold water supplies.
Slide the escutcheons over the supply pipes and against the
finished wall. Tighten the setscrews to secure the escutcheons in
place.
Install the supply stops to the supply pipes and tighten securely.
Apply thread sealant to the threads of the compression fittings,
add the plated nuts, and install the supply stops.
Tighten securely using a clean strap wrench.
Install the stirrup handle to the control fitting with the plated
screw, and tighten securely.
1-3/4" (4.4 cm)
4-1/2"
(11.4 cm)
1-7/8"
(4.8 cm)
6-1/2"
(16.5 cm)
Water
Supply
Wall
Bracket
Supply
Pipe
Stirrup
Handle
Supply Stop
Lock Washer
Support
Bracket
Control
Fitting
Wall Support
Tube
Plated
Screw
Supply Stop
Compression
Fitting
Hex Nut
Plated Nut
Escutcheon
Setscrew
Fastener
Kohler Co.
3