Summary of Contents for K-1188-RE

Page 1: ...e Overflowing Bath M product numbers are for Mexico i e K 12345M Los n meros de productos seguidos de M corresponden a M xico e j K 12345M Fran ais page Fran ais 1 Espa ol pagina Espa ol 1 K 1188 K 11...

Page 2: ...drowning Use this unit only for its intended use as described in this manual Do not use attachments not recommended by Kohler Company Do not operate this unit without the guard cover on the suction fi...

Page 3: ...confident its dependability and beauty will surpass your highest expectations satisfying you for years to come All information in this guide is based upon the latest product information available at...

Page 4: ...el to the drain The channel sensors should be completely covered with water The green light in the pump control switch will start to blink automatically within 1 2 minute after the sensors are submerg...

Page 5: ...lights will begin to cycle through each of the colors sweep mode The control switch flashes blue in the sweep mode When the chromatherapy lights are in sweep mode you can lock in one color light by p...

Page 6: ...o lock an individual chromatherapy color in press the chromatherapy specific color icon Programming the Remote IMPORTANT Programming the remote control is required Your whirlpool will not respond to a...

Page 7: ...ess the pump control switch button and let the unit run for 5 to 10 minutes Press the pump control switch button a second time to turn off the unit Completely drain the unit Wipe the surface dry with...

Page 8: ...n a negligent fashion and as a consequence has suffered damages attributable to the consumer individual or hardware not authorized by Kohler Co 3 This warranty does not cover the damages as a result o...

Page 9: ...ice activated B Check for blockage of the motor vent Allow the motor to cool then remove the blockage Check for a plugged metal suction screen and allow the motor to cool before restarting Check for b...

Page 10: ...s damaged B Replace wiring harness Refer to the installer dealer C Remote control not programmed correctly C See remote control Homeowners Guide or Service Manual D Remote control does not work D Repl...

Page 11: ...Service Parts Finish color code must be specified when ordering Kohler Co 11 1019731 5 C...

Page 12: ...ls Plug Wire Assembly RE Models Plug Wire Assembly 1020079 RE Models Plug Wire Assembly 1010618 Elbow 1012821 Light Housing 73519 Water Level Probe 60129 Nut 60129 Nut 63270 Washer 1021777 Wire Harnes...

Page 13: ...Removal Tool 1004262 Suction Screen 1004861 Handle 1004243 Base 1004263 Screen 69472 Washer 94822 D Screw 65226 Suction Plug 65054 Screw 1003065 96895 Suction Cover 96708 Flange 65886 Gasket 93685 Hou...

Page 14: ...4 Adapter 1019447 B Isolation Mount 93192 Screw 1001794 Locknut 1019720 Pump Bracket 1018964 Heater Bracket 1019433 Carriage Bolt 90153 Nut Finish color code must be specified when ordering 67065 Grou...

Page 15: ...utterfly Assy 94821 O Ring 94821 O Ring 94821 O Ring 1034673 Connector 1005363 Nut Butterfly Motor Service Parts Detail 96956 Butterfly Kit 63149 Screw 50506 Screw 1016466 Motor See below for butterfl...

Page 16: ...and 1013464 D Decal 1023091 Cap 1013471 Stand 1022253 D Remote 1013822 E RE Models Remote w Stand 1013464 E Decal 1023091 Cap 1013471 Stand 1022253 E Remote Finish color code must be specified when or...

Page 17: ...mie L hyperthermie a lieu lorsque la temp rature corporelle interne atteint plusieurs degr s au dessus de la temperature normale de 98 F 37 C Les effets de l hyperthermie comprennent a d faut de perce...

Page 18: ...er les num ros de mod le et de s rie ci dessous localis s pr s de la pompe de la baignoire hydromassage Mod le No _________________________ No s rie __________________________ Sommaire Informations de...

Page 19: ...un espace de tranquillit et de rajeunissement et remplira gracieusement votre vie pour les ann es venir Cette baignoire d versement l vera l ambiance spirituelle et l exp rience de l immersion corpor...

Page 20: ...ndant le fonctionnement de la baignoire d versement Remplir toujours l unit avec une temp rature d sir e pour votre niveau de confort Remplir l unit avec de l eau de fa on ce que le bassin d borde dan...

Page 21: ...chromath rapie Si les lumi res chromotiques sont teintes presser le bouton de contr le de lumi re situ c t de l interrupteur de contr le de la pompe Les lumi res de chromath rapie commenceront le cycl...

Page 22: ...ouleurs presser sur l ic ne du cycle de chromath rapie Pour verrouiller une couleur de chromath rapie individuelle appuyer sur l ic ne de couleur de chromath rapie correspondante Programmer la t l com...

Page 23: ...versement et le trop plein du drain jusqu immerger compl tement les deux capteurs du niveau La lumi re verte de l interrupteur de la pompe clignotera automatiquement 30 secondes apr s que les capteur...

Page 24: ...cer le contr le Contacter l installateur vendeur 2 Le produit ne d marre pas A Pas d alimentation l unit A Alimenter l unit ou corriger la perte de courant Contacter l installateur vendeur B L eau ne...

Page 25: ...e niveau d eau est insuffisant dans le canal de trop plein B Remplir le bassin de mani re ce que l eau circule par dessus le rebord du bassin dans le canal de trop plein et submerge les capteurs Le ni...

Page 26: ...tr le Contacter l installateur vendeur 9 L eau n atteint pas le rebord de la baignoire pendant le remplissage A Pas d alimentation l unit A Brancher l alimentation lectrique B C bles de la sonde de ni...

Page 27: ...Pi ces de rechange Vous devez sp cifier les codes de la finition et ou de la couleur quand vous passez votre commande Kohler Co Fran ais 11 1019731 5 C...

Page 28: ...les RE Mod les RE Sonde du niveau d eau crou crou Harnais de c blage Pompe Interrupteur Couronne Logement Plaque de mise niveau Ensemble prise c ble Ensemble prise c ble Ensemble prise c ble Ensemble...

Page 29: ...004263 Grille 69472 Rondelle 94822 D Vis 65226 Bouchon 65054 Vis 1003065 96895 96708 Flange 65886 Joint 93685 Logement 73518 Bouchon Voir au dessus pour les d tails de la grille d aspiration Capuchon...

Page 30: ...Vis 1001794 Contre crou 1019720 Support de pompe 1018964 Support de chauffe eau 1019433 Boulon de carrosserie 90153 crou Vous devez sp cifier les codes de la finition et ou de la couleur quand vous pa...

Page 31: ...821 Joint torique 94821 Joint torique 1034673 Connecteur 1005363 crou D tail de pi ces de rechange papillon moteur 96956 Kit papillon 63149 Vis 50506 Vis 1016466 Moteur Voir ci dessous pour le service...

Page 32: ...71 Support 1022253 D T l commande 1013822 E Mod les RE T l commande avec support 1013464 E D calcomanie 1023091 Capuchon 1013471 Support 1022253 E T l commande Vous devez sp cifier les codes de la fin...

Page 33: ...uperior a la temperatura corporal normal de 98 F 37 C Los efectos de la hipertermia incluyen a incapacidad para percibir calor b incapacidad para reconocer la necesidad de salir de la ba era c inconsc...

Page 34: ...ue y anote a continuaci n los n meros de modelo y serie cerca de la bomba de la ba era de hidromasaje No de modelo _________________________ No de serie __________________________ Contenido Informaci...

Page 35: ...ncia que podr disfrutar durante muchos a os La ba era rebosante crear un ambiente de relajaci n y serenidad con la inmersi n total del cuerpo el agua de la cascada y el suave movimiento del agua en su...

Page 36: ...la unidad con agua a la temperatura que le parezca agradable Llene la unidad de manera que el agua de la ba era se desborde al canal de rebose y al desag e Los sensores del canal deben estar totalmen...

Page 37: ...oterapia Si las luces de cromoterapia est n apagadas oprima el bot n del interruptor de control de la luz ubicado junto al interruptor de control de la bomba Las luces de cromoterapia empezar n a camb...

Page 38: ...de cromoterapia Para seleccionar un color de cromoterapia en particular oprima el icono del color espec fico de cromoterapia Programaci n del control remoto IMPORTANTE Es necesario programar el contro...

Page 39: ...es del canal de rebose La luz verde del interruptor de control de la bomba empezar a parpadear autom ticamente 1 2 minuto despu s de que los sensores del canal de rebose se encuentren sumergidos por c...

Page 40: ...recomienda al consumidor que conserve el recibo o factura de compra como protecci n adicional pues el mismo puede sustituir a la garant a en caso de que exista discrepancia en cuanto a la validez de l...

Page 41: ...la ba era al canal de rebose y cubra los sensores del canal de rebose Se recomienda llenar hasta el rebosadero de desag e C El interruptor de control de la bomba no se enciende ni se ilumina de forma...

Page 42: ...de agua en el canal de rebose es insuficiente B Llene la ba era hasta que el agua se desborde por el borde de la ba era al canal de rebose y cubra los sensores del canal de rebose Se recomienda llenar...

Page 43: ...rde de la ba era una vez llena A La unidad no tiene alimentaci n el ctrica A Active la alimentaci n el ctrica B Los cables de la sonda de nivel est n sueltos B Revise vuelva a conectar el cableado Con...

Page 44: ...Piezas de repuesto Se debe especificar el c digo del acabado color con el pedido 1019731 5 C Espa ol 12 Kohler Co...

Page 45: ...cables Modelos RE Montaje de enchufe cables 1020079 Modelos RE Montaje de enchufe cables 1010618 Codo 1012821 Alojamiento de luz 73519 Sonda de nivel de agua 60129 Tuerca 60129 Tuerca 63270 Arn s de...

Page 46: ...4861 Manija 1004243 Base 1004263 Rejilla 69472 Arandela 94822 D Tornillo 65226 Tap n de succi n 65054 Tornillo 1003065 96895 Tapa de succi n 96708 Brida 65886 Empaque 93685 Alojamiento 73518 Tap n Vea...

Page 47: ...Contratuerca 1019720 Soporte de la bomba 1018964 Soporte del calentador 1019433 Perno de cabeza de hongo 90153 Tuerca Se debe especificar el c digo del acabado color con el pedido 67065 Leng eta de c...

Page 48: ...lo 94821 Arosello 1034673 Conector 1005363 Tuerca Detalle de las piezas de repuesto de la v lvula de mariposa y del motor 96956 Kit de la v lvula de mariposa 63149 Tornillo 50506 Tornillo 1016466 Moto...

Page 49: ...023091 Tapa 1013471 Soporte 1022253 D Control remoto 1013822 E Modelos RE Control remoto con soporte 1013464 E Calcoman a 1023091 Tapa 1013471 Soporte 1022253 E Control remoto Se debe especificar el c...

Page 50: ...1019731 5 C...

Page 51: ...1019731 5 C...

Page 52: ...USA 1 800 4 KOHLER Canada 1 800 964 5590 M xico 001 877 680 1310 kohler com 2007 Kohler Co 1019731 5 C...