background image

Product Information

Drop-in rim style

K-1162P-H

shown

Fixture*:

basin area

top area

weight

Bathing well

43

(109.2 cm) x

24-5/8

(62.5

cm)

53-1/2

(135.9

cm) x 32-1/8

(81.6 cm)

110 lbs

(50 kg)

water depth

capacity

To overflow

15

(38.1 cm)

57 gal (215.9 L)

* Approximate measurements for comparison only.

Pump:

HP

V

Hz

A

1-speed

1.25

120

60

7.5

Heater

kW

V

Hz

A

1.5

120

60

12.5

Minimum access panel pump/control:
20

(50.8 cm) W x 15

(38.1 cm) H

required

Included Components:
Cut-out template

1042556-7

Required Electrical Service (2 required)

Two dedicated circuits required, each protected with Class A

Ground-Fault Circuit-Interrupter (GFCI):
Pump/control

120 V, 15 A, 60 Hz

Heater

120 V, 15 A, 60 Hz

Notes

Install this product according to the installation guide.
Floor support under whirlpool must provide for a minimum of

80 lbs/square foot (390 kg/square meter) loading.
The suction line extends 4-3/4

(12.1 cm) beyond the edge of the

rim. The pump base extends 1/8

(3 mm) beyond the edge of the

rim. Modify the framing as needed.
This fixture conforms to CSA B45 and ANSI Standard Z124.1. All

dimensions are nominal.

21" 
(53.3 cm)

Pump/Control 
Access

19-1/2" 
(49.5 cm)

21"

 

(53.3 cm)

1-1/2"
(3.8 cm)

3-1/8"
(7.9 cm)

3-1/2" 
(8.9 cm)

1-1/2" OD

10-13/16" (27.5 cm)

60" (152.4 cm) 

42" (106.7 cm)

4-5/8" (11.7 cm)

3/8" (1 cm)

3" (7.6 cm)

2-7/8" (7.3 cm)

Drop-In Rim Detail

Recommended faucet area

No change in measurements if connected with 
drain illustrated. (K-11677 or K-11677M)

1041938-1-B

2

Kohler Co.

Summary of Contents for K-1162

Page 1: ...da M product numbers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA 1 800 4 KOHLER Canada 1 800 964 5590 México 001 877 680 1310 kohler com K 1162 1041938 1 B 2006 Kohler Co ...

Page 2: ...GFCI Pump control 120 V 15 A 60 Hz Heater 120 V 15 A 60 Hz Notes Install this product according to the installation guide Floor support under whirlpool must provide for a minimum of 80 lbs square foot 390 kg square meter loading The suction line extends 4 3 4 12 1 cm beyond the edge of the rim The pump base extends 1 8 3 mm beyond the edge of the rim Modify the framing as needed This fixture confo...

Page 3: ...CI Pompe contrôle 120 V 15 A 60 Hz Chauffe eau 120 V 15 A 60 Hz Remarques Installer ce produit selon le guide d installation Le support du sol sous la baignoire à hydromassage doit pouvoir fournir une charge minimale de 80 lbs pieds carrés 390 Kg m2 La ligne d aspiration se prolonge de 4 3 4 12 1 cm au delà du rebord de l arête du rebord La base de la pompe se prolonge de 1 8 3 mm au delà de l arê...

Page 4: ... de circuito con pérdida a tierra GFCI de Clase A Bomba control 120 V 15 A 60 Hz Calentador 120 V 15 A 60 Hz Notas Instale este producto conforme a la guía de instalación El soporte del piso debajo de la bañera de hidromasaje debe poder sostener una carga mínima de 80 libras pie cuadrado 390 kg metro cuadrado La línea de succión sobresale 4 3 4 12 1 cm del filo del borde La base de la bomba sobres...