background image

Product Information

Applicable product:
Drop-in rim style, right-hand pump with

heater

K-1160-H

Tile flange, right-hand pump with heater

K-1160-FH

Fixture*:
Bathing well:
Basin area, bottom

52” (132.1 cm) x 38-3/4” (98.4 cm)

Basin area, top

61” (154.9 cm) x 46-1/4” (117.5 cm)

Weight

131 lbs (59.9 kg)

To overflow:
Water depth

15” (38.1 cm)

Capacity

96 gal (363.6 L)

* Approximate measurements for comparison only.

V

Hz

A

Pump: 1-speed

120

60

7.5

Heater: 1.5 kW

120

60

12.5

Minimum access panel

pump/control (required):

20

(50.8 cm) W x

15

(38.1 cm) H

Required Electrical Service (2 required)

Two dedicated circuits required, each protected with Class A

Ground-Fault Circuit-Interrupter (GFCI):
Pump/control

120 V, 15 A, 60 Hz

Heater

120 V, 15 A, 60 Hz

Locate the outlets behind the whirlpool and within 24

(61 cm)

of the pump and heater.

Notes

Install this product according to the installation guide.
Floor support under this product must provide for a minimum of

39 lbs/square foot (189 kg/square meter) loading.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions

are nominal.

1-1/2" OD

3" (7.6 cm)

60" (152.4 cm)

27-1/2" (69.9 cm)

135˚

135˚

Recommended faucet area

35"
(88.9 cm)

63"
(160 cm)

60"
(152.4 cm)

35"
(88.9 cm)

29" (73.7 cm)

13-1/8"
(33.3 cm)

4-7/8"
(12.4 cm)

43-3/4"
(111.1 cm)

19-1/2"
(49.5 cm)

21"
(53.3 cm)

1/2" (1.3 cm)

2-7/8" (7.3 cm)

2-7/8" (7.3 cm)

57-1/2"
(146.1 cm)

Drop-In Rim Style

Cut-Out Detail

Drop-In

Rim Detail

1-1/2"
(3.8 cm)

No change in measurements if connected with
drain illustrated. (K-11677 or K-11677M)

29"
(73.7 cm)

Tile Flange

Detail

Pump/Control Access

1-1/4"
(3.2 cm)

1042005-1-C

2

Kohler Co.

Summary of Contents for K-1160-H

Page 1: ...umbers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA Canada 1 800 4KOHLER México 001 877 680 1310 kohler com K 1160 H K 1160 FH 1042005 1 C 2009 Kohler Co ...

Page 2: ... 120 V 15 A 60 Hz Heater 120 V 15 A 60 Hz Locate the outlets behind the whirlpool and within 24 61 cm of the pump and heater Notes Install this product according to the installation guide Floor support under this product must provide for a minimum of 39 lbs square foot 189 kg square meter loading This fixture conforms to ANSI Standard Z124 1 2 All dimensions are nominal 1 1 2 OD 3 7 6 cm 60 152 4 ...

Page 3: ...ommande 120 V 15 A 60 Hz Chauffe eau 120 V 15 A 60 Hz Localiser les prises derrière la baignoire à hydromassage et dans une distance de 24 61 cm de la pompe et du chauffe eau Remarques Installer ce produit selon le guide d installation Le support du sol sous ce produit doit pouvoir soutenir une charge minimale de 39 lbs pied carré 189 kg mètre carré Ce meuble est conforme au standard ANSI Z124 1 2...

Page 4: ...omba control 120 V 15 A 60 Hz Calentador 120 V 15 A 60 Hz Coloque los tomacorrientes detrás de la bañera de hidromasaje y a menos de 24 61 cm de la bomba y del calentador Notas Instale este producto conforme a la guía de instalación El soporte del piso debajo de este producto debe poder soportar una carga mínima de 39 lbs pie cuadrado 189 kg metro cuadrado Este producto cumple con la norma Z124 1 ...

Reviews: