Kohler GM100956-KP1 Installation Instructions Manual Download Page 10

10

TT-1379

5/16

Note:

Always identify and correct the cause of a fault

shutdown before resetting the controller. Consult

the operation manual for guidance and items to

check.

Digital Gauge Fault Codes

Fault codes are displayed on the gauge when a fault
condition is detected.

See Figure 19 for faults displayed on the gauge for units
equipped with an ADC 2100 controller.

See Figure 20 for faults displayed on the gauge for units
equipped with an ADC II or ADC IId controller.

See Figure 21 for faults displayed on the gauge for units
equipped with a Decision-Maker

r

3500 controller.

Units with ADC 2100 Controller

Digital Gauge

Display

Description

LOP

Low Oil Pressure

OC

Over Crank

OS

Over Speed

LCL

Low Coolant Level

LOC

Loss of Coolant

AF

Auxiliary Input Fault

HE

High Engine Temperature

OU

Over Voltage

UU

Under Voltage

OF

Over Frequency

UF

Under Frequency

LB

Low Battery Voltage

HB

High Battery Voltage

Figure 19

Fault Codes Displayed on the Gauge (for

Units Equipped with an ADC 2100

Controller)

Units with ADC II or ADC IId Controller

Digital Gauge

Display

Description

LOP

Low Oil Pressure

OC

Over Crank

OS

Over Speed

AF

Auxiliary Input Fault

HE

High Engine Temperature

OU

Over Voltage

UU

Under Voltage

OF

Over Frequency

UF

Under Frequency

LB

Low Battery Voltage

HB

High Battery Voltage

Figure 20

Fault Codes Displayed on the Gauge (for

Units Equipped with an ADC II or ADC IId

Controller)

Units with Decision-Maker

r

3500 Controller

Digital Gauge

Display

Description

LOP

Low Oil Pressure

OS

Over Speed

AF

Auxiliary Input Fault

HE

High Engine Temperature

OU

Over Voltage

UU

Under Voltage

OF

Over Frequency

UF

Under Frequency

For other possible fault codes, the gauge displays:

SHdn

(for a Shutdown) or

Alrt

(for an Alert/Warning).

Check the interface on the Decision-Maker

r

3500 Controller for more

details.

Figure 21

Fault Codes Displayed on the Gauge (for

Units Equipped with an Decision-Maker

r

3500 Controller)

Summary of Contents for GM100956-KP1

Page 1: ...of the remote digital gauge s start stop function requires that the jumper is enabled on the Advanced Digital Control ADC generator sets shipped from the factory already have the jumper enabled Refer to the wiring diagram in the generator set operation manual if the jumper was disconnected from terminals 1 and 2 on the P7 connector continuous power mode Note For generator sets with an ADC 2100 con...

Page 2: ...fainting or death Carbon monoxide is a poisonous gas present in exhaust gases Carbon monoxide is an odorless colorless tasteless nonirritating gas that can cause death if inhaled for even a short time Carbon monoxide poisoning symptoms include but are not limited to the following D Light headedness dizziness D Physical fatigue weakness in joints and muscles D Sleepiness mental fatigue inability to...

Page 3: ... Kits For Units with an ADC Controller For units with a Decision Makerr 3500 controller order a remote extension harness kit See Figure 4 for kit selection DO NOT exceed 91 4 m 300 ft CAN network length Remote Extension Harness Kit Number Length m ft As Shown In GM91774 KP1 7 6 25 Figure 11 GM91774 KP2 15 2 50 GM91774 KP3 30 5 100 GM92053 KP1 7 6 25 Figure 12 GM92053 KP2 15 2 50 GM92053 KP3 30 5 1...

Page 4: ...ects to the remote digital gauge connector Connects to the generator set customer interface connector or a remote harness connector Figure 7 Remote Gauge Harness GM32325 Included with Kit GM32337 KP1 GM30248 15 ft Extension Harness Kit GM32333 KP1 25 ft Extension Harness Kit GM32333 KP2 Figure 8 Remote Extension Harness Kits For Use With Kit GM32337 KP1 GM33846A D Figure 9 Harness Connection Diagr...

Page 5: ...M91774 KP2 100 ft Extension Harness Kit GM91774 KP3 Figure 11 Remote Extension Harness Kits For Use With Kit GM100956 KP1 GM100997 25 ft Extension Harness Kit GM92053 KP1 50 ft Extension Harness Kit GM92053 KP2 100 ft Extension Harness Kit GM92053 KP3 Figure 12 Remote Extension Harness Kits For Use With Kit GM100956 KP1 GM100996 Y Harness Kit GM92054 KP1 Figure 13 Y Harness Kit For Use With Kit GM...

Page 6: ...6 TT 1379 5 16 GM88254 B Sheet 1 of 2 Sheet 2 of 2 Figure 15 Interconnection Diagram For Kit GM100956 KP1 ...

Page 7: ...he controller may automatically power down and go into Sleep Mode to conserve battery power This will occur after one hour of inactivity only when the CAN parameter is set to Cn06 If the CAN parameter is set to Cn01 the controller will remain powered and will draw battery power See TT 1364 for more information ADC 2100 Controller CAN Setting Power Down Time Application Notes Cn01 Never None J1939 ...

Page 8: ...s until the gauge beeps and the display changes 6 Use the UPorDOWNbuttonsto selecteither Intor USA units 7 Press and hold both the UP and DOWN buttons until the gauge beeps and the display changes 8 Press the DOWN button 9 The gauge displays ESC 08 10 Press and hold both the UP and DOWN buttons until the gauge switches to the monitor mode GM30565 B 1 Fault indicator 2 Arrow if blinking indicates t...

Page 9: ...the AUTO position for remote start stop If the ADC 2100 master switch is in the RUN position a remote stop command will not stop the generator set The arrow at the top left side of the display blinks to indicate that the generator set is running see Figure 17 item 2 Note The ADC II and ADC IId must be powered display active for remote start stop Note The Decision Maker 3500 must be powered display...

Page 10: ...uency LB Low Battery Voltage HB High Battery Voltage Figure 19 Fault Codes Displayed on the Gauge for Units Equipped with an ADC 2100 Controller Units with ADC II or ADC IId Controller Digital Gauge Display Description LOP Low Oil Pressure OC Over Crank OS Over Speed AF Auxiliary Input Fault HE High Engine Temperature OU Over Voltage UU Under Voltage OF Over Frequency UF Under Frequency LB Low Bat...

Page 11: ...TT 1379 5 16 11 Notes ...

Page 12: ...s Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone 65 6264 6422 Fax 65 6264 6455 Availability is subject to change without notice Kohler Co reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever Contact your local Kohlerr generator set distributor for availability 2004 2006 2012 and 2016 by Kohler Co All rights...

Reviews: