Using spirit level plumb
Door Assembly. Tape into
position as indicated.
14
Fit long seal to hinge edge of
glass. Flap faces into
enclosure. Push down to butt against
bottom seal. Trim to top of glass.
16
If door alignment is incorrect, door
will not function properly and
further adjustments are necessary.
Remove tape and re-align until
correct alignment is achieved.
DO NOT PROCEED TO STEP 15 UNTIL
DOOR IS OPERATING CORRECTLY.
NOTE: This is an important part of
the installation procedure and your
careful attention at this stage will
ensure that you will obtain the best
possible results.
IMPORTANT
TEST THE OPENING AND CLOSING
OPERATION OF THE PIVOT DOOR.
SILICONE APPLICATION
18
(b)
Hold tube at 45° angle and push
(c)
The surface of the sealant can
be smoothed (before surface dries)
small quantity of water with one drop
of washing-up liquid added.
(d)
Excess silicone should be
removed immediately with a damp
cloth.
(e)
Allow the silicone 24 hours to
cure before using the enclosure.
CAUTION: Avoid contact with skin,
eyes and mouth and avoid breating
with water. If irritation persists, seek
medical attention. Keep out of reach
of children.
IMPORTANT
SILICONE SEALANT SHOULD BE
APPLIED TO ALL OUTSIDE JOINTS.
DO NOT SEAL FROM INSIDE.
Seal these areas:
A - Full height between retainers
and walls.
B - Between door sill and tray.
C - Between retainer and door
jamb to a height of 100mm.
(a)
Cut tip of Silicone Tube Nozzle
at 45° angle.
Ensure all joints are clean and
dry before applying sealant.
For sealant application, follow
steps (a) to (e) below.
clear silicone is required.
silicone is required.
IMPORTANT
Fit handles following instruc-
tions supplied with handle.
17
Drill holes (use 2.5mm drill bit,
DO NOT USE A BIGGER DRILL
BIT) through punched holes at top
and bottom of each wall retainer to
secure door. Fix screws as pictured.
Fit caps & remove positioning tape.
15