COMPONENTS

5mm

3mm

Slider Rail

Water Delivery

System

Roller Securing Caps

Splashguard

Aligning

Roller

Blanking

Cap

Water Delivery

Top Caps

Water Delivery Wall

Jamb & Wall Channel

Glass Panel

x13

A

x3

C

x5

B

x13

3mm

6mm

OR

Fixed Head

Water Delivery

System

2m Pipe and

Connector

Electrical

Cable

TROUBLESHOOTING

The  information below gives details on what you can do as a user should you encounter difficulties whilst 

operating the shower.

If there is a problem with the shower control some of the push buttons will flash very fast.

Malfunction  

Cause  

Remedy

Push buttons are
flashing on the shower
control and / or the
shower will not operate

No flow or low flow rate
from the Shower Fittings

Drip from spray plate
assembly on handset

Incorrect shower
temperature

Water supply isolated

Damaged or broken cable
connection

Electrical supply isolated
or fuse blown

Digital Mixer Valve 
breakdown

Spray plate assembly
blocked

Hose blocked or twisted

A small amount of water
may be retained in the
shower fitting after the
shower control has been
turned off. This may drain
over a few minutes

Digital Mixer Valve  
malfunction

Maximum temperature
incorrectly set

Digital Mixer incorrectly
fitted

Check water supply

Check cable connections

Check electrical supply

Isolate product and turn
back on after 30 seconds

If the problem still
persists note the
sequence of the flashing
push buttons and
contact Customer
Services

Refer to Cleaning

Clear blockage or
release twist in hose

This is quite normal.
Changing the angle of
the shower fitting may
vary the draining time

Solenoid fault. May
require cleaning or
replacement. Contact
Customer Services

Refer to Commissioning,
Maximum temperature
setting

Make sure that the hot
and cold water supplies
are connected correctly

RH

LH

Door

Stop Vinyl

NOTE:

The Water Delivery

System is supplied

attached to the Wall

Jamb & Wall Channel

Summary of Contents for CFI230G

Page 1: ...ra Magna Shower System 646 Fitting Instructions 1 2 3 4 1 2 3 4 Slide Rail Fixed Head Kohler Daryl Limited Alfred Road Wallasey Wirral CH44 7HY England Tel 44 0 151 606 5000 Fax 44 0 151 638 0303 www...

Page 2: ...olumn box The Shower Enclosure is subject to the Daryl Showering Lifetime Guarantee and for the Shower System the Mira Showers 5 year guarantee applies Please refer to the Guarantee Registration Docum...

Page 3: ...r Daryl Glass Treatment and Daryl Glass Protector Available in one care kit the Treatment and Protector are used on new or existing shower installations where Protector has not already been applied an...

Page 4: ...ith a pH value of 4 to 8 applied with a soft cloth Under no circumstances should scourers or powerful detegents be used as these can damage the metallic surface of the frame and also tarnish the glass...

Page 5: ...ctrical supply isolated or fuse blown Digital Mixer Valve breakdown Spray plate assembly blocked Hose blocked or twisted A small amount of water may be retained in the shower fitting after the shower...

Page 6: ...of the glass panel fits into slot A on the tray The wall channel end sits on the flat section of the tray B A B Handset Adjustment To adjust the height of the handset press the release button A and sl...

Page 7: ...tart Soothe and Massage and an Eco setting To adjust the spray setting turn the spray plate as follows 1 Start Water flows from the outer set of holes To select the Start setting turn the spray plate...

Page 8: ...r To Operate the Shower 1 Press the Low Medium or High flow push button 2 Water will come out of the handset at the desired temperature 3 To alter the showering temperature turn the temperature contro...

Page 9: ...STEP 17 Take care not to damage pipe and cable protruding from wall The lock mode may be activated when the unit is OFF in which case the unit cannot be switched ON unless the mode is cancelled as ab...

Page 10: ...d momentarily hold the Warm Up and High keys at the same time Release the push button and reselect within 2 seconds The two keys will flash twice and beep three times to confirm the selection is succe...

Page 11: ...EP 22 Note The lintel is supplied as a RH unit For LH versions loosen the panel clamps and turn them through 180o Ensure glass panels are parallel to each other Loosely fit the parking block into the...

Page 12: ...screw B on each panel clamp until it grips the glass IMPORTANT DO NOT OVER TIGHTEN Fit caps to lintel C A B Remove the lintel from glass and remove the parking block 1 Match parking block to mark on...

Page 13: ...he Suppression Ferrite close to the Water Delivery connector Note The Suppression Ferrite is packed with the Digital Mixer Fit the fixed roller to the tray on the same side as lintel wall fixing Note...

Page 14: ...ller and plastic glass guide Caution Whilst supporting the weight of the door slide the bottom roller into the bottom track Caution 14 CFI230G 15 CFI230G STEP 32 STEP 33 STEP 31 STEP 35 STEP 37 STEP 3...

Reviews: