To install supply shut-off valve
Install toilet supply shut-off valve so it is 140mm above
floorline and 135mm to the left of the centerline of the
closet flange. Centerline of supply shut-off outlet should
extend 102mm from finished wall. Install the supply shut-
off valve with outlet vertcial.
140mm
135mm
102mm
305
140
135
Supply Shut-Off Valve
Closet Flange
Centerline
5
Install the wax seal.
Wax Seal
NOTE 1:
NOTE 2:
Wax ring type toilet gasket should not be installed at
temperatures less than 21
.
If you are using a toilet gasket with an integral
plastic sleeve, make sure the gasket is positioned with the
sleeve facing away from the toilet.
If you temporarily plugged the closet flange with a rag,
remove the rag at this time and ensure that the drain pipe is
clear and free of debris.
1
21
2
6
Apply weight evenly.
Do not move after placement!
Watertight seal may be broken!
7
Do not
overtighten.
Install floor mounting kit as shown in the figure.
This side up.
-4-