Kohler 8881T-UC01-AF Installation Instructions Manual Download Page 3

1100331-SP-BN

1196535

-SP

-AF

1115769-SP

16306T-NA

8881T-VC01-BN
8881T-VC03-BN
8881T-UC01-BN
8881T-UC03-BN

8881T-VC01-AF
8881T-VC03-AF
8881T-UC01-AF
8881T-UC03-AF

8881T-VC01-BN

8881T-VC01-AF

8881T-UC01-BN

8881T-UC01-AF

8881T-VC03-BN
8881T-VC03-AF

8881T-UC03-BN
8881T-UC03-AF

PRODUCT PAGE

产品图

Slurry Mold

灰浆模套

Flushing Control Stick

冲洗控制棒

Hex Pan
2.5mm

内六角扳手

1100331-SP-BN
1196535-SP-AF
Panel

面板

1092297

-SP

Senosor Lens

透明条

Gasket

垫圈

1205586

-SP

1205587-SP

Electronic Unit Assy.

电控盒组件

Control 

box bracket

电控盒支架

1115769

-SP

Battery Box,Assy

电池盒组件

Valve Body

主体

Inlet Connection

进水接头

Anti-Rotating Sheet

防转片

Nut

螺母

Gasket

橡胶垫圈

Screw M4X50

螺钉

 M4X50

Screw, M3X8

螺钉

 M3X8

1100691

-SP

Assy, Filter 

滤网组件

O-ring
O

型圈

1088695

-SP

Valver Cover

阀盖

O-ring
O

型圈

1056081

-SP

Solenoid Valve

电磁阀

ACL-219G202-SP
Pressing Board

压片

1100658

-SP

Bracket Assy

固定架底板组件

Screw M3X8

螺钉

M3X8

O-ring
O

型圈

Valve Cover

止水阀盖

Pressing Board

压片

Screw M3X8

螺钉

 M3X8

Screw M2.5X6

螺丝

 M2.5X6

Screw M3X12

螺钉

 M3X12

Screw M3X22

螺钉

 M3X22

Lock Nut

吊紧螺母

Valve Box

暗盒

1100693-SP
Diaphragms Assy

膜片组件

Adjustment Bolt Assy

调节螺栓组件

Connector

连接件

Outlet Connection

出水接头

Screw M3X8

螺钉

M3X8

Restrictor

节流器

O-ring
O

型圈

Valve Body Assy 

主体组件

O-ring
O

型圈

16306T-NA
AC

交流电源盒

1145332-SP
Connector

接插件组件

1205586

-SP

8881T-VC01-BN
8881T-VC01-AF

8881T-VC03-BN
8881T-VC03-AF

1205587

-SP

8881T-UC01-BN
8881T-UC01-AF

8881T-UC03-BN
8881T-UC03-AF

1206437-T01-A

3

Summary of Contents for 8881T-UC01-AF

Page 1: ...n to proper installation read all operating and safety instructions All information in these instructions is base upon the latest product information available at the time of publication Kohler China...

Page 2: ...is 0 10MPa no more than 1L 0 18 0 55MPa 1L 0 1MPa 1L 8881T VC01 BN AF 1L DC 8881T VC03 BN AF 1L AC 0 18 0 55MPa 0 5L 0 1MPa 0 5L Water pressure at 0 18 0 55 MPa average flushing is no more than 0 5L W...

Page 3: ...Body Inlet Connection Anti Rotating Sheet Nut Gasket Screw M4X50 M4X50 Screw M3X8 M3X8 1100691 SP Assy Filter O ring O 1088695 SP Valver Cover O ring O 1056081 SP Solenoid Valve ACL 219G202 SP Pressi...

Page 4: ...149 320 40 523 83 126 149 320 40 150 83 126 149 K 5016T YER K 5016T YET 320 40 486 83 126 149 150 83 126 149 358 320 40 486 358 83 126 149 K 18645T Y 0 420 40 455 K 4960T ET K 4960T ER 320 40 523 83...

Page 5: ...A as top inlet use stainless steel hose as rear inlet c To ensure an effective flush performance an urinal with corresponding flush volume is required And the urinal should comply with ASME A112 19 2...

Page 6: ...he flush valve with supporting block to make it flat and straight Then connect the inlet pipe According to the dimensions of the urinal stall the outlet fitting are connected and installed as shown in...

Page 7: ...ed to electric control box by connection wire 3 16306T NA a b 220V c Outlet downwards Outlet upwards Connect to sensor Connect AC Power Supply Connect to sensor Connect AC Power Supply A 1 2 AC Connec...

Page 8: ...f which the nominal section area of conductor is not less than 0 5mm2 is also recommend DC connection line use wire of which the nominal section area is not less than 0 3mm2 It is cut according to act...

Page 9: ...e around the valve box Lay the tiles 40 Valve Box Tiles Slurry Mold 4 5 While using DC power take out the battery box from the back side of cover Loose the screws of the battery box assy with a screw...

Page 10: ...shing Control Stick 1 30 8 10 2 If the urinal is used continuously the urinal will flush every 2 minutes automatically The urinal enters into working status after the power is connected for 10 seconds...

Page 11: ...se the valve turn off the fixed cap with screw driver Take out the valve core filter assy and clean with a brush and reinstall them Turn off the water supply or tighten the adjusting bolt before clean...

Page 12: ...h a brush Please make following checks before repair Symptoms Probable causes Corrective actions If the trouble remains after above mentioned actions are taken please contact with us via distributor N...

Page 13: ...sensor directly 7 Urinal is designed or use with potable water Avoid water that includes a lot of contaminants or acid alkali water and impure water 8 When AC power unit is connected to 20V AC power s...

Reviews: