1287816-2A-B
2
1287816-2A-B
3
INSTALLATION CHECKOUT
CLEANING INSTRUCTIONS
All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft
cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc, which could adversely
affect the finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings.
INSTALLATION
How to Install the Faucet
Use appropriate thread sealants or thread tape on
pipe threads. Install the two offset connectors(1) into
the hot and cold supply pipes.
Adjust the center-to-center distance between the
connectors to 150mm and horizontally. They should
extend 29mm from finished wall. Thread the
escutcheons(2) onto the connectors until they contact
the finished wall.
Put the washers(3) into the nuts(4). Thread the nuts
onto the connectors(1) and tighten by wrench.
How to Install the Handshower
Remove the guard on the outlet connector firstly.
Put the washer(5) into end A of the hose(6), and then
connect to the faucet outlet(7). Put the washer(8) into
end B of the hose, and install the regulator(9) into the
handshower(10) inlet if needed, then connect end B of
the hose to the handshower inlet.
How to Install the Bracket
Determine a suitable location on the finished wall to
install the bracket. Mark bracket base mounting hole
locations on the wall according to the dimension. Drill
two holes on the finished wall, the holes should match
the anchors(11). Install the anchors.
Tighten screws(12) to secure bracket base(13, flat
side upward). Put the bracket(14) onto the bracket
base and lock by stopper.
Ensure that all coupling nuts tightened.
Ensure that the handle is in the off position.
Turn on the main water supply, and check for leaks.
Repair as needed.
74036T-4E2: Wall Mount Bath Shower Faucet
Remove the handshower(10), remove the aerator(16)
by coin. Run hot and cold water through the faucet for
about one minute to remove any debris. Check for
leaks. Remove any debris from the aerator.
Lift the diverter(15) gently, turn clockwise for shower.
Run hot and cold water through the faucet for about
one minute to remove any debris. Check for leaks.
Shut off the faucet, reinstall the handshower and
aerator .
74035T-4E2: Wall Mount Shower Faucet
Remove the handshower(10). Run hot and cold water
through the faucet for about one minute to remove
any debris. Check for leaks. Shut off the faucet,
reinstall the handshower.
Cold
Hot
1
2
150mm
29mm
27
12
14
13
11
10
8
7
9
B
5
A
6
10
15
16
10
3
4
1500
G1/2˝
G1/2˝
G1/2˝
87
Ø90
226
49
40º
27
60
58
74035T-4E2
G1/2˝
G1/2˝
56
130
150±15