Section 6 Controller Troubleshooting
Is there AC output
when the start button
is HELD and the unit
is running?
Is AC output at the
correct voltage, e.g.
120 volts AC?
Yes
Test the voltage
regulator Refer to
Section 7
No
Replace the
controller
circuit
board
Yes
Is there 12VAC output at the
B1/B2 stator winding?
No
Yes
Is there 12VDC at
the exciter field?
Yes
Test the
stator
and main
field
No
No
Separately excite the
generator set to
determine if other
components are
inoperative.
Replace the
controller
circuit
board
Yes
No
Is AC output voltage at
spec (See Section 7,
Separate Excitation)?
Test the stator,
main field (rotor), and
exciter/armature.
Refer to Section 7
Is the voltage
regulator
fuse okay?
Yes
Replace the fuse
No
(OPTIONAL)
Go to B at the beginning
of the preceding page
C
Test the voltage
regulator. Refer to
Section 7
Figure 6-6
Troubleshooting Relay Controller Circuit Board (4 of 4)
Summary of Contents for 27EFOZ
Page 1: ...Marine Generator Sets Models 32EOZ 27EFOZ TP 5936 7 04d Service...
Page 2: ......
Page 4: ...TP 5936 7 04 Table of Contents Notes...
Page 10: ...TP 5936 7 04 VI Safety Precautions and Instructions Notes...
Page 16: ...TP 5936 7 04 4 Section 1 Specifications Notes...
Page 20: ...TP 5936 7 04 8 Section 3 Intake Exhaust System Notes...
Page 30: ...TP 5936 7 04 18 Section 5 Cooling System Notes...
Page 38: ...TP 5936 7 04 26 Section 6 Controller Troubleshooting Notes...
Page 48: ...TP 5936 7 04 36 Section 7 Generator Troubleshooting Notes...
Page 52: ...TP 5936 7 04 40 Section 8 Component Troubleshooting Notes...
Page 61: ...TP 5936 7 04 49 Section 10 Voltage Reconnection and Wiring Diagrams Notes...
Page 68: ...TP 5936 7 04 56 Section 10 Voltage Reconnection and Wiring Diagrams Notes...
Page 77: ......
Page 78: ......
Page 79: ......