Message
Type
Description
Advance Diagnostic Active
Status
During any exercise mode, shutdown occurs due to any other
condition(Fault) excluding Emergency Shutdown, Main Power
Overloaded Shutdown, Low Cranking Voltage Shutdown.
Advance Diagnostic Active Ended
Status
Advance Diagnostic mode is ended
Always On
Notice
Any of the following optional boards are connected to controller
1. LCM
2. PIM
Ats Exercise Active
Notice
The generator is in exercise mode.
ATS Exercise mode End Prematurely
Status
Exercise mode ends prematurely.
Ats Loaded Test Active
Status
The ATS contactor position is source2 and user places the
controller in RUN mode.
Ats Position Source 1 selected
Status
The ATS contactor position is source1.
Ats Position Source 2 selected
Status
The ATS contactor position is source2.
ATS Test End
Status
ATS Test ended.
Ats Test Ended Prematurely
Status
ATS Test ended prematurely.
Ats Unloaded Test Active
Status
Generator is started by pressing RUN Button.
Auto Recovery
Status
Unit has reset due to unexpected error.
Backup Parameter Loaded
Status
Test event log command is initiated from Site Tech.
Default Parameters Loaded
Status
When the engine stops, status is updated.
Diagnostic Exercise Active
Status
Variable speed exercise is running.
Emergency Power System Supplying
Load
Notice
The utility power is absent and the generator is powered on.
This notice is displayed on SiteTech.
Engine Cool Down Active
Notice
The generator is in cool down mode.
Engine Start Delay Active
Notice
The engine start delay is active.
Engine Started
Status
When the engine starts, status is updated.
Engine Stopped
Status
When the engine stops, status is updated.
Exercise mode End
Status
Exercise mode ended.
File System Error
Status
Parameter/event saving fails after 3 retries.
Forced to Auto Status
Status
Mode has changed to AUTO mode.
Generator Running
Notice
The engine is started and a valid engine speed has been
achieved. This notice is displayed in SiteTech.
Load Priority X Shed
Notice
Priority X (1- 6) load with is disconnected.
Loaded Full Speed Exercise Active
Status
Loaded full speed exercise is running.
Maintenance Timer Reset
Status
The user has reset the maintenance timer.
Normal Power Source Unavailable
Notice
Utility power is unavailable.
Remote Start
Status
The remote start switch is pressed.
Unloaded Full Speed Exercise Active
Status
Unloaded full speed exercise is running.
Figure 2-6