14 Scheduled Maintenance
TP-6334
9/04
3.5 Gaseous Fuel System
The gaseous fuel system utilizes a fuel valve (with
solenoid) to control the fuel flow to the fuel regulator.
The
generator-mounted
regulator
reduces
fuel
pressure as fuel passes to the carburetor.
See
Figure 3-4. The carburetor controls the ratio of fuel to air
under varying loads and speed conditions. Because the
carburetor receives fuel in a gaseous state, it does not
have to provide vaporization of the fuel.
FE-255000-G
2
1
1. Gas fuel valve
2. Gas fuel regulator
Figure 3-4 Fuel Regulator and Valve
3.5.1 Carburetor (LP Vapor)
Generator sets are equipped with an emission certified
engine. No adjustments can be made. Contact an
authorized service distributor/dealer about adjustments
for altitude performance on emission certified engines.
3.6 Air Cleaner
At the interval specified in the service schedule, inspect,
clean,
or replace
the air cleaner element. Clean the
element more frequently in dirty, dusty conditions.
Check the element for accumulated oil or dirt that could
cause poor performance.
Replace a damaged air
cleaner element.
Follow the procedure described
below.
Air Cleaner Service Procedure
A dry-type air cleaner silences and filters the intake air.
The air intake silencer assembly connects to the intake
manifold via a flexible hose. Refer to Figure 3-5 during
this procedure.
1. Release the spring clips to open the housing and
remove the air silencer element.
2. Tap the element lightly against a flat surface to
dislodge loose surface dirt.
Do not clean the
element in any liquid or use compressed air as
these will damage the filter element.
3. Examine the element and housing for damage.
Replace the element or housing if necessary.
4. Wipe the cover and base with a clean rag to remove
dirt. Make sure the sealing surfaces fit correctly
and reattach the spring clips.
A-226955
1. Cover
2. Spring clip(s)
3. Housing
4. Pressure tap,
(1/8--27 NPT)
5. Element
6. Dust ejector
1
2
3
4
5
6
Figure 3-5
Air Cleaner
Summary of Contents for 10ERG
Page 1: ...Commercial Mobile Generator Sets Model 10ERG 13ERG 15ERG TP 6334 9 04 Operation...
Page 4: ......
Page 10: ...VI Safety Precautions and Instructions TP 6334 9 04 Notes...
Page 14: ...TP 6334 9 04 2 Service Views Notes...
Page 20: ...8 Operation TP 6334 9 04 Notes...
Page 38: ...TP 6334 9 04 26 Section 5 Wiring Diagrams GM28747A C Figure 5 1 Wiring Diagram Sheet 1 of 2...
Page 39: ...TP 6334 9 04 27 Section 5 Wiring Diagrams GM28747B C Figure 5 2 Wiring Diagram Sheet 2 of 2...
Page 40: ...TP 6334 9 04 28 Section 5 Wiring Diagrams ADV6846A A Figure 5 3 Schematic Diagram Sheet 1 of 2...
Page 41: ...TP 6334 9 04 29 Section 5 Wiring Diagrams ADV6846B A Figure 5 4 Schematic Diagram Sheet 2 of 2...
Page 42: ...TP 6334 9 04 30 Section 5 Wiring Diagrams GM33846 A Figure 5 5 Accessory Wiring Diagram...
Page 46: ......
Page 47: ......