This should not be overtightened. Move the control lever fully
downwards and check that the left hand micro-switch operates the
igniter and that the control valve spindle is fully depressed. Move the
control lever upwards to the “off” position and check that the right hand
(cut-off) micro-switch operates. Check that the control lever operates
smoothly and safely.
NOTE : The cable is factory set, and therefore should need no adjustment
p)
Refit the front burner heat shield to the sides of the fire box (2 Screws)
and secure the trim to the fire using the magnets provided.
q)
Before making the final gas connection, thoroughly purge the gas
supply pipework to remove all foreign matter, otherwise serious
damage may be caused to the gas control valve on the fire
.
The other firebox fixing method is as follows :-
In installations where the cable method is not suitable (e.g. loose masonary in rear
of fire opening) the firebox can be secured to the fire surround using four screws
and wall plugs provided. Below (figure 13) is a diagram to indicate the hole centre
positions available on the firebox to facilitate the screw fixing to the fireplace /
surround.
Fig. 13
18
532mm
260mm
37mm
Firebox
Mounting
Flange
425mm