background image

If  removing  pipes  is  difficult  because  the  piping  space  is  very 
constricted,  consult  your  nearest  Koganei  sales  office  for  a 
specialized tool that is available.

 

Specialized tools for removing tubes

Handling instructions and precautions

 Usable tubes

Use  of  both  nylon  tubing  and  urethane  tubing  are  supported.  
Nylon  tubing  outside  diameter  precision  should  be  within 

±

0.1 

mm [

±

0.004 in] (nominal) for nylon tubing and within 

±

0.15 mm 

[

±

0.006 in] (nominal) for urethane tubing. Use tubing with ovality 

(difference  between  major  axis  and  minor  axis)  within  0.2  mm 
[0.008 in] (use of Koganei tubing is recommended).  Use of tubing 
that  is  not  a  Koganei  genuine  product  or  a  compatible 
(recommended)  product  may  result  in  tube  disconnection,  air 
leakage,  or  other  problems.  Be  sure  to  check  on  tubing  before 
building a pneumatic system.  Also, note that you cannot use the 
conductive urethane tube U2A-B produced by Koganei.

φ

1.8 [0.071]

φ

3 [0.118]

φ

4 [0.157]

φ

6 [0.236]

φ

8 [0.315]

φ

10 [0.394]

φ

12 [0.472]

Tube size

Minimum bending radius

̶

4 [0.157]

Nylon tube

Urethane tube

̶

7 [0.276]

20 [0.787]

10 [0.394]

30 [1.181]

15 [0.591]

50 [1.969]

20 [0.787]

80 [3.150]

27 [1.063]

150 [5.9]

35 [1.378]

mm [in]

NOTE

1.  Use tubing with an exterior that is not damaged.  If tubing 

becomes  damaged  after  repeated  use,  cut  off  the 
damaged portion.

2.  Do  not  allow  tubing  to  become  severely  bent  or  twisted 

near the connection to a fitting.  Such a condition creates 
the  risk  of  air  leakage.   The  table  below  shows  minimum 
radius guidelines for nylon and urethane tubing.

3.  Do  not  use  extremely  soft  tubing,  which  causes  a  severe 

drop in pull-out strength.

4.  Before removing any tubes, always turn off the air supply.  

Also,  be  sure  to  confirm  that  the  air  inside  the  pipes  is 
completely vented before starting.

 Speed adjustment for actuators

 To increase the speed

  Start with the needle of the speed 

controller  fully  closed  and  turn  it 
counterclockwise  to  increase  the 
speed of the actuator.  When you 
reach the desired speed, be sure 
to tighten the lock nut so that the 
speed setting does not deviate.

 To decrease the speed

  If you turn the needle of the speed 

controller too far (the speed is too 
fast), turn it clockwise to decrease 
the  speed.   When  you  reach  the 
desired  speed,  be  sure  to  tighten 
the  lock  nut  so  that  the  speed 
setting does not deviate.

For 

φ

3 [0.118], 

φ

4 [0.157], and 

φ

6 [0.236] tubes

 

Order codes: 

UJ-1

For 

φ

6 [0.236], 

φ

8 [0.315], 

φ

10 [0.394], and 

φ

12 [0.472] tubes

 

Order codes: 

UJ-2

03̲2016

Summary of Contents for SSU4

Page 1: ...g pressure range 0 05 MPa 7 psi Cracking pressure Operating temperature range Recommended tube Sales unit Union Straight type Remarks Gasket or seal is already attached Elastic sleeve NBR Sealant coated Tube Release ring Polyacetal Lock claw Stainless steel Tube end Plastic body Polybutylene terephthalate Metal body Brass electroless nickel plated For M3 threads SUS303 equivalent Lock nut Aluminum...

Page 2: ...ock on hand The SSU M is the replacement model Dimensions mm Union straight SSU 2 φD 2 φP F3 F2 B1 F1 2 C B2 B3 E 2 φd Model Tube outer diameter φD B1 B2 B3 φP E C φd F1 F2 F3 Mass g MAX MIN SSU4 4 28 6 25 9 20 4 20 4 10 5 11 14 9 3 2 14 6 5 6 5 13 SSU6 6 42 5 36 5 24 9 24 9 13 15 16 9 4 3 20 8 5 11 29 SSU8 8 47 3 41 1 27 4 27 4 15 18 18 1 4 3 22 9 5 12 43 SSU10 10 53 5 45 9 31 7 31 7 18 21 20 7 4...

Page 3: ...on straight SSU 2 φD 2 φP F3 F2 B1 F1 2 C B2 B3 E 2 φd Model Tube outer diameter φD B1 B2 B3 φP E C φd F1 F2 F3 Mass oz MAX MIN SSU4 0 157 1 126 1 020 0 803 0 803 0 413 0 433 0 587 0 126 0 551 0 256 0 256 0 459 SSU6 0 236 1 673 1 437 0 980 0 980 0 512 0 591 0 665 0 169 0 787 0 335 0 433 1 023 SSU8 0 315 1 862 1 618 1 079 1 079 0 591 0 709 0 713 0 169 0 866 0 374 0 472 1 517 SSU10 0 394 2 106 1 807...

Page 4: ...Pa Number of needle rotations Pressure MPa 0 1000 1500 500 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 500 1000 1500 1 2 3 4 5 6 7 8 9 10 11 12 13 0 7 0 5 0 3 0 1 Flow rate R min ANR Flow rate R min ANR Controlled flow Free flow MPa Number of needle rotations Pressure MPa Flow Rate Characteristics Union Straight Type SSU4 SSU6 SSU8 SSU10 SSU12 End of March 2015 Sales limited to stock on hand The SSU M is th...

Page 5: ...Tube end Precautions for mounting fitting Precautions for attaching tubes Use the appropriate tool to tighten the hex nuts on the fitting Refer to the following table of recommended tightening torques when attaching the threaded parts If you use more than the recommended torque when tightening the threaded parts you may cause leaks by fracturing the threads or deforming the gaskets Also if you use...

Page 6: ... 3 150 27 1 063 150 5 9 35 1 378 mm in NOTE 1 Use tubing with an exterior that is not damaged If tubing becomes damaged after repeated use cut off the damaged portion 2 Do not allow tubing to become severely bent or twisted near the connection to a fitting Such a condition creates the risk of air leakage The table below shows minimum radius guidelines for nylon and urethane tubing 3 Do not use ext...

Page 7: ...sure type meter out BK Low pressure type meter in AG High flow rate type meter out Text engraved on top of needle knob K Low pressure type White Standard meter out Low pressure type meter out Black Standard meter in Low pressure type meter in Mark on top of needle knob Needle knob Made of black plastic Mark on top of needle knob Needle knob Made of black plastic Needle knob Has one line Needle kno...

Reviews: