background image

Temperature characteristics

Small Precision Pressure Gauge

1.

The small precision pressure gauge is a pressure indicator
designed for more sensitive pressure measurements. Avoid use
in locations subject to vibrations or shocks.

2.

The throttle valve uses an extremely small orifice for protection
from shock pressure transmitted to the Bourdon tube and other
internal devices, and is therefore sensitive to intrusions of
particles, sludge mist, and other contaminants. For the media,
use clean, dry air that has passed through a mist filter, etc.

Preset marker

Small Precision Pressure Gauge

1.

The guaranteed temperature accuracy range is 25°C

±

5 [77

±

9°F]. Check the ambient temperature of the measurement
location before proceeding with measurement.  

2.

If the temperature is out of the guaranteed temperature accuracy
range, perform a pressure compensation by multiplying the
ambient temperature by the humidity coefficient 0.05% F.S./°C.

3.

In performing pressure compensation, add plus or minus in
accordance with temperature characteristics, subtractin

when

the temperature is at 30°C or higher, and adding when the
temperature is at  20°C or lower.

Example: The measured value is 0.2MPa and the ambient
temperature is 40°C (the pressure 

compensation

value is 

±

0.00015MPa)

(Even after performance of pressure compensation, there is an error of 

±

1% F.S.)

Small Pressure Gauge,
Pressure Gauge

Preset markers can be used on the
pressure gauges G1-40 and G3-40.
Rotate the cover ring first to set the low
pressure side, and then set the high
pressure side.

P

0

P

1

±

0.00015

×

(T

1

T

2

)

P

0

0.2

0.00015

×

10

P

0

0.1985MPa

P

0

: Actual pressure (MPa)

P

1

: Measured pressure (MPa)

T

1

: Guaranteed accuracy temperature (°C)

T

2

: Ambient temperature (°C)

4.

If not performing pressure compensation, the pressure indication
accuracy value is accurate within the operating temperature
range shown on the temperature characteristics graph. Be aware
that the ambient temperature can change the indicated accuracy.

5.

The graph below positions 25°C [77°F] as the standard
temperature, and shows the amount of change from the
indicated accuracy at 25°C [77°F] required for the ambient
temperature to come within the operating temperature range, in
terms of percent of full scale (F.S.).

6.

The temperature characteristic lines shown in the graph below
are representative examples only. Individual products will exhibit
some variance from these lines in terms of characteristics. 

7.

The chain line       shows the indicated accuracy 

±

1% F.S.,

while the dotted line           shows the amount of change required
for the ambient temperature to come within the operating
temperature range, calculated using the humidity coefficient. The
figures within the framed area     show the compensation range.

-5

+3

+2

+1

0

-1

-2

-3

0

10

25

40

60

50

Ambient temperature

Operating temperature range

% F.S. indicated accuracy

Low pressure
side marker

High pressure
side marker

Cover ring

176

Small Pressure Gauge, Pressure Gauge, Panel
Mounting Pressure Gauge
Small Precision Pressure Gauge, 

V

acuum Gauge

Mounting and piping

Small Pressure Gauge, Pressure Gauge, Small Precision
Pressure Gauge, 

V

acuum Gauge

1.

While any mounting direction is acceptable, install a throttle
mechanism, etc., 

W

hen mounting bet

w

een a valve and actuator,

or other location 

w

here pressure fluctuation can be intense.

2.

When mounting and piping a pressure gauge, never grab the
pressure gauge body for the purpose of tightening. To tighten,
always use a wrench on the hexagonal or square section of the
connection port. The tightening torque should be at 294.2N

cm

[26.0in.

lbf] or less.

Panel Mounting Pressure Gauge

 Panel Mounting Pressure Gauge (GP1-

4

0, GP

-4

0,

GPV-40)

1.

When mounting the panel mounting pressure gauge on a panel,
machine the mounting holes in accordance with the panel cut
dimensions. (See the  panel cut dimensions)

2.

Since the panel mounting pressure gauge in its packaged
condition already has the pressure gauge assembled into the
panel mount assembly, always remove the mounting ring from
the assembly and then mount on a panel for use.

3.

When mounting on a panel, first align the convex section of the
back side of the panel mounting case flange to the small hole
used for positioning on the panel cut hole (see Figure 1).

4.

The tightening torque for the mounting ring used to secure 
the panel mounting case in position should be 980.7N

cm

[86.8in.

lbf] or less.

5.

If removing the pressure gauge itself from the panel mounting
case, first remove the mounting ring, and then pull up on the tab
located on the bottom of the panel mount case. The pressure
gauge can now be easily removed by pushing it out. Be aware
that forcibly attempting to remove the pressure gauge without
first pulling on the tab could damage the convex section inside
the tab that is used to prevent falling. (see Figure 2)

Panel mounting assembly (PM-40)

If purchasing the pressure gauge and panel
mounting assembly separately, take the
following steps when combining them to use as
the panel mounting pressure gauge.

1.

Remove the mounting ring from the panel
mounting case, and insert the square part of
the pressure gauge connection port into the
square part at the bottom of the case.

2.

When inserting, check that (1) the two set screws on the back of
the pressure gauge case are on the lower side, and (2) two set
screw holes are found on the bottom of the panel mounting
case's square part. After confirming the above two items, push in
the pressure gauge.

3.

With the unit in the inserted position, check to see that the
convex section at the bottom of the panel mounting case that is
used to prevent falling is inserted into the mounting hole (

φ

2.3)

[0.091in.] at the bottom of the pressure gauge case. If the
pressure gauge and panel mounting case have been assembled
correctly, the insertion tab will snap smoothly into place. If it does
not go in smoothly, lift up on the tab and the unit should then
slide in easier (see Figure 3).

Figure 1

Figure 2

Figure 3

(

PM-40

)

Handling Instructions and Precautions

Convex portion

Convex portion
(opposite side)

Panel mounting case

Panel cut hole

Small hole used 
for positioning

Insertion tab

φ

2.3 Mounting hole

Summary of Contents for EG110

Page 1: ...INSTRUCTION MANUAL Ver 1 0 BKUA002 Ver 1 0 PRESSURE GAUGE Air Treatment ...

Page 2: ... Small Precision Pressure Gauge Vacuum Gauge Mounting and piping Small Pressure Gauge Pressure Gauge Small Precision Pressure Gauge Vacuum Gauge 1 While any mounting direction is acceptable install a throttle mechanism etc When mounting between a valve and actuator or other location where pressure fluctuation can be intense 2 When mounting and piping a pressure gauge never grab the pressure gauge ...

Page 3: ...e has been added for snap in connection to quick fittings 10 R1 8 18 75 13 13 5 75 31 5 34 8 φ21 8 5 0 1 0 Width across flats Order Codes Direction method of piping A Bottom piping D Back piping DPL Back piping plug in For handling instructions and precautions see p 176 G 1 20 Pressure gauge Outer diameter 20mm 0 79in Pressure indication range 1 Standard specification 1MPa 145psi G1 20A 34 3 10 21...

Page 4: ... 40 G3 40 G6 40 G1 40 G3 40 G6 40 Symbol Specifications Dimensions of Pressure Gauges mm 46 40 6 26 5 R1 4 φ42 5 M5 0 8 14 Width across flats 0 8 0 2 0 1 0 6 0 4 MPa Order Codes Outer diameter 40 Outer diameter 40mm 1 57in For handling instructions and precautions see p 176 G 40 Pressure gauge Pressure indication range 1 Standard specification 1MPa 145psi 3 Low pressure specification 0 3MPa 44psi ...

Page 5: ...ts case Equipped with quick fittings for fast piping installation Outer diameter 40 Outer diameter 40mm 1 57in For handling instructions and precautions see p 176 GP 40 Panel mounting pressure gauge Note Panel mounting pressure gauges are supplied with quick fittings φ4 straight type and elbow type Pressure indication range 1 Standard specification 1MPa 145psi 3 Low pressure specification 0 3MPa 4...

Page 6: ...uges mm Compact yet assures full scale pressure indication accuracy of 1 Can also be used as a panel mounting pressure gauge Mechanical operating life of 200 000 full scale FS operations with built in throttle valve Outer diameter 40 Outer diameter 40mm 1 57in Scale plate Blank NO throttle valve S With throttle valveNote1 Notes 1 Throttle valves are to be sold separately 2 Panel mounting type is s...

Page 7: ...80 100 0 kPa 46 26 5 19 5 12 6 φ 42 5 14 R1 4 M5 0 8 Depth 5 Port size Blank R1 4 01 R1 8 Non ion specification Blank Standard specification NCU Non ion specification GPV 400 Panel mounting vacuum gauge For handling instructions and precautions see p 176 For the panel cut dimensions see p 173 Outer diameter 40 Outer diameter 40mm 1 57in 20 40 60 80 100 0 kPa 44 26 5 17 5 10 4 φ 42 5 14 R1 8 M5 0 8...

Page 8: ...tc Detection Do not put wires or other foreign objects inside the pressured area This product is for use with non corrosive gases Be aware that it cannot be used with liquids or with corrosive gases Mounting Always thoroughly blow off use compressed air or air blowing the tubing before piping Be careful to prevent chips sealing tape or rust etc generated during plumbing from entering into the pipe...

Page 9: ...uge has always had difficulty with and without worries about breakage The pressure gauge comes equipped with an LED analog indication using a semiconductor pressure transducer The electronic mode without any mechanical moving parts assures longer operating life better reliability and higher precision than the Bourdon tube pressure gauge Front side Rear side EG110 EG120 EG121 Connection port R1 4 I...

Page 10: ... 2 dot display Indication cycle 10ms or less Red LED when output is ON lights up Red LED when power supply is ON lights up 490kPa 71psi 1 47MPa 213psi Air or non corrosive gas DC12 24V 10 ripple tolerance P P 10 or less 40mA or less NPN transistor open collector equipped with short circuit protection function Maximum inrush current 100mA Applied voltage DC30V max Residual voltage 1V max inrush cur...

Page 11: ...lue shown in the figure above or greater 4 Conformity DIN43700 Pressure indicator Red Pressure indicator Red Power supply indicator Red Operation indicator Red Connection port R1 4 M5 0 8 Depth 6 40 14 40 30 54 48 6 13 EG120 EG121 front display EG110 front display Pressure setting indicator Pressure setting dial 1 2 DOT Indicator Green Operation indicator Red 1 2 DOT Indicator Green φ3 7 cable 0 5...

Page 12: ...reen LED 1 2DOT offers pressure indication at higher resolution Example EG120 Example EG110 Open NO type GND connection NC type Pressure setting dial Pressure scale MPa 0 2 0 4 0 6 0 8 1 0 Pressure setting indicator 2 1 3 20 40 60 80 Pressure scale kPa Pressure scale kPa 20 40 60 80 EG121 Indicated pressure 40kPa 42 5kPa 45kPa 20 40 60 80 20 40 20 40 Green LED lights up Indicated pressure 0 8MPa 0...

Page 13: ...act so that the contacts are touching the exposed wires Caution For the connector type the connector wiring position at time of delivery is in the connecting thread side back side Cautions 1 To regulate the pressure do not remove the cap on the lens surface but insert a small screwdriver into a slit in the cap instead and directly rotate the pressure regulation screw 2 The pressure needle has a in...

Page 14: ... Non ion specification Item Model GS1 50 Air 0 83 120 5 60 41 140 0 1 0 0 145 F S 3 0 1 0 83 14 120 0 05 7 0 05 7 5 45 C 41 113 F 0 07 10 max Micro switch a contact NO Lead wire length About 500mm 19 7in Note 2 DIN connector Standard equipment LED for DC neon lamp for AC 9 8 1 Any 0 17 6 0 0 19 6 7 with DIN connector Aluminum die casting SPCC Brass Brass Media Maximum operating pressure MPa psi Op...

Reviews: