background image

 How to Connect to Wiring for Power Supply and Abnormal Output Contracts 

Inside of the ionized air outlet

Cotton swab

LOW

HIGH

3

2

1

FLOW

H V

ALARM

POWER

(1)

 

Connect the supplied the Power Supply Signal Cable to the connector on the 

backside of the main unit. 

(2)

 

Connect the + 24 V line of the DC power supply to the "red" line, and 0 V line to the 
"green" line of the Power Supply Signal Cable, respectively. 

(3)

 

If the Abnormal Output Contacts are to be used, connect the Contact to the “White” 
and “Black” lines of the Power Signal Cable. No polarity is involved with the 

connections in this case. 

 

         

Caution 

Make sure that the connections are carried out in a secure manner by using a terminal 

block or crimp-style terminals, etc. Otherwise, main unit gets damaged. 
If the abnormal output circuits are to be used, make sure the circuits are used within 

the rated specification range (24 VDC; 50 mA, max.).  Otherwise, the main unit may 
possibly be damaged. 
See the diagram below for the abnormal output circuits. 
The abnormal output circuits will start working about 2 seconds after the power is 

turned on.    Pay special attention when designing the abnormal detection circuits to be 
incorporated in the system. 
If no abnormal output circuits are to be used, be sure to carry out some appropriate 
measures for insulating the "white" and "black" tail ends of the supplied Power Supply 
Signal Cable. Otherwise,

 m

ain unit gets damaged. 

 
 
 
 
 
 
 
 
 

 How to Ground the Wiring 

(1)

 

Connect the round terminal of the supplied Grounding Lead Wire to the grounding 

terminal located on the backside of the main unit. 

(2)

 

Connect the terminal at the opposite end of the Grounding Lead Wire to the 

grounding point. 

 

         

Caution 

0V line and grounding terminal are connected common line in main unit. 

 

         

Caution 

Confirm that the grounding point is properly grounded. If it is not, be sure to carry out 

the grounding procedure (according to the 3rd class procedure). 
The product must be properly grounded. Otherwise, an electric shock accident or a 

malfunction of the unit may occur. In addition, the product may not be able to work up 

to the full performance. 

 

6. Operation 

6.1  Operations When Turning ON the Power 

(1)

 

Check the product to confirm that the setting and wiring have been carried out in 
accordance with the instructions given under Section 5. "Installation/Wiring" in this 

manual. 

(2)

 

Turn ON the switch on the DC power supply. 

(3)

 

Press once the power switch (push-button type) located on the front of the product. 

The power will be supplied to the product. If the unit is operating normally, both the 
power switch and high-voltage power supply LED (green) located on the front side of 

the product will light up. 

(4)

 

In accordance with the distance to the charged object and the amount of static 
electricity charged on the object, adjust the Airflow Adjustment Knob to provide the 

appropriate amount of airflow. 

 

         

Caution 

If the Power Switch of the unit or the high-voltage LED does not light up, or if the alarm 

display on the front of the unit lights up, immediately turn off the power from the unit. 
Then, check the installation and wiring against the instructions given under Section 5. 

"Installation/Wiring." In case you cannot solve the problem even then, please refer to 

Section 7. "Maintenance" and Section 8. "Troubleshooting." 

 

6.2  Operations When Turning OFF the Power 

(1)

 

Press once the Power Switch (push-but the type) located on the front of the product. 

Both the Power Switch and their high-voltage LED on the front of the product will go 

off. 

 

7.  Maintenance 

          Warning 

Maintenance is an extremely important factor for achieving the optimum performance 
of the device. Be sure to carry out the maintenance work on a regular basis. 
Before you perform the maintenance work, make sure that the Power Supply Signal 
Cable has been disconnected. 
When you are using solvent such as alcohol, make sure that the room is well 
ventilated. And if you have used alcohol for cleaning, make sure that all alcohol has 

evaporated and no part on the main unit is wet with alcohol. 
The tip of the Discharge Needle is pointed. When removing or cleaning the Discharge 

Needle Unit, pay special attention to the Discharge Needle Unit, or else you may injure 

yourself. Be careful not to cause the Discharge Needle to be bent or broken, otherwise, 
the performance of the unit may be greatly degraded. 

 

 

7.1

 

How to Clean the Discharge Needle 

The material used for the Discharge Needle of this product is tungsten. Tungsten as the 

material for Discharge Needles is very durable and will not wear off easily. If the product 
is regularly maintained in a normal manner, almost no degradation of the performance 

will be observed. 

 If the Discharge Needle Unit is not to be removed: 

(1)

 

Confirm that the cable is not connected to the connector on the Backside of the main 
unit. If connected, disconnect the cable

.

 

(2)

 

Soak the supplied Discharge Needle Cleaning Brush in anhydrous alcohol such as 
isopropyl alcohol. Use the brush to remove the foreign particles

 

attached to the tip of 

the Discharge Needle. 

 
 
 
 
 

(3)

 

If the inside of the ionised air outlet is soiled, moisten a cotton swab with anhydrous 
alcohol such as isopropyl alcohol and wipe off the soiled surfaces with the swab.  

Note that cotton swabs are not supplied with a main unit as an accessory item.  

Please prepare them by yourself when using them. 

 
 

 
 
 

         

Caution 

If cleaning of the Discharge Needle is to be carried out without removing the Discharge 

Needle Unit, it is possible that dust may be splashed when the unit is operated after the 

cleaning work is completed due to the lack of cleaning of the backside of the Discharge 
Needle and to falling of dust into the internal part of the main unit.    It is recommended, 

therefore, that you perform the cleaning work by removing the Discharge Needle Unit. 

 If the Discharge Needle Unit is to be removed: 

(1)

 

Confirm that the cable is not connected to the connector on the Backside of the main 
unit. If connected, disconnect the cable. 

(2)

 

In accordance with 7.2 “How to Replace the Discharge Needle Unit,” remove the 
Discharge Needle Unit. 

(3)

 

Soak the supplied Discharge Needle Cleaning Brush in anhydrous alcohol such as 
isopropyl alcohol. Use the brush to remove the foreign articles attached to the tip of 

the Discharge Needle. 

 
 
 
 
 
 
 
 
 

(4)

 

If the board of the Discharge Needle Unit is soiled, moisten a piece of waste cloth 

with anhydrous alcohol such as isopropyl alcohol and wipe off the soiled surfaces 

with the cloth. 

 
 
 
 
 

 
 
 

In accordance with 7.2 “How to Replace the Discharge Needle Unit,” install the Discharge 
Needle Unit. 

         

Caution 

The tip of the Discharge Needle is sharply pointed.    Pay special attention to handling of 
the Discharge Needle Unit after it is removed from the unit. 
If the soil on the tip of the Discharge Needle cannot be removed by cleaning, or if the 
Discharge Needle is bent or broken by an accident, etc., replace the Discharge Needle 

Unit with new one in accordance with 7.2 

"

How to Replace the Discharge Needle Unit." 

If you continue to use the unit without replacing the defective needle, the performance 
may be degraded or insufficient static elimination may occur. 

 

7.2  How to Replace the Discharge Needle Unit (DTRY-ZEM-W22) 

The material used for the Discharge Needle of this product is tungsten. Tungsten as the 

material for Discharge Needles is very durable and will not wear off easily. If the product 
is regularly maintained in a normal manner, almost no degradation of the performance 

will be observed. In case, however, contamination cannot be removed due to negligence 

of maintenance or the Discharge Needle is bent or damaged due to an accident, etc., 
replace the entire Discharge Needle Unit with a new one. 

(1)

 

Confirm that the cable is not connected to the connector on the backside of the main 
unit. If connected, disconnect the cable. 

(2)

 

Unscrew the set screws (or the Knurl Screws) of the Discharge Needle Unit. 

 
 
 
 
 
 
 
 

(3)

 

While securely holding the Bracket section of the Discharge Needle Unit, pull it out in 

a straight line. 

 
 
 
 
 
 
 
 
 

         

Caution 

The tip of the Discharge Needle Unit is sharply pointed.  Pay special attention when 
handling of the Discharge Needle Unit. 

 

(4)

 

Prepare a new Discharge Needle Unit. 

(5)

 

While securely holding down the main unit, insert the Discharge Needle Unit into the 

plug-in inlet of the main unit until the Discharge Needle unit is securely locked in the 

main unit. 

 
 
 
 

 
 
 
 
 

         

Caution 

When inserting the Discharge Needle Unit into the main unit, insert it through the slits 

(black) provided at both ends of the plug-in inlet of the main unit. 
Insert the Discharge Needle Unit into the main unit in a straight line without applying 

excessive force, or else a malfunction of the unit may occur. 
When inserting the Discharge Needle Unit into the main unit, be careful not to touch the 

air outlet of the main unit at Discharge Needle. 

 

(6)

 

Tighten the set screws (or the Knurl Screws) of the Discharge Needle Unit to lock 
the unit at the specified position. 

 

         

Caution 

Make sure that screws are fully tightened.    A niece grew not fully tightened may cause 

defective operations of the unit or may prevent the unit from operating up to the full 

performance. 

 

7.3  Discharge Needle Unit: How to Attach Knurl Screws 

(1)  Check the connectors on the back side of the main unit to confirm that no cable is 

connected.    If any cable is connected, disconnect it. 

(2)  Dismantle the Discharge Unit (DTRY-ZEM-W22) in accordance with the specified 

method of replacement. 

(3)  Align a drop-out protection washer with each of the screwing positions for the 

Discharge Unit and screw in a knurl screw on each of the 2 positions. 

 
 
 
 
 
 
 

(4)  Install the Discharge Unit (DTRY-ZEM-W22) in accordance with the specified 

method of replacement. 

 

         

Caution 

The tip of the Discharge Needle is extremely sharp and pointed.  Pay special 
attention in working with the Discharge Needle Unit while it is being dismantled. 
A Drop-out Protection Washer is a very small item.    Be especially careful not to 
misplace it. 
When dismantling the Discharge Unit from the Main Unit, do not give a Knurl 

Screw a strong pull, or else the Drop-out Protection Washer may come off. 

 

7.4  How to Exchange the Filter (DTRY-ZFU-W22) 
         

Caution 

The Filter is a consumable item.  When deterioration of the Filter is observed, 
replace it with a new one. 
When the Filter Cover is soiled or the Filter is clogged, the product cannot achieve 
its full performance.    Be sure to carry out regular maintenance. 

 

(1)

 

Confirm that the cable is not connected to the connector on the backside of the main 
unit. If connected, disconnect the cable. 

(2)

 

In accordance with “How to Remove a Filter,” remove the Filter. 

(3)

 

Wipe off the soil from the Filter Cover using a piece of waste cloth soaked with 
anhydrous alcohol such as isopropyl alcohol. 

(4)

 

Mount the newly prepared Filter in the Filter Cover. 

(5)

 

Close the Filter Cover and lock it on the main unit using Knurl Screws. 

 

 
 
 
 
 
 

         

Caution 

Make sure that the Knurl Screws are fully tightened.  Any Knurl Screws not fully 

tightened may cause the Filter Cover to be disengaged while the unit is used, or may 
cause some noise to be generated. 

 

7.5 Inspection 

(1)

 

Check the Power Supply Signal Cable to confirm that there is no deterioration or 
breaking in the insulation. 

(2)

 

Check the power supply voltage and the width of its variation to ensure that they are 

within the specified range. 

(3)

 

Check the main unit to confirm that there is no unknown noise generated from the 

unit. 

 

8. Troubleshooting 

In case any abnormal condition is observed in this product, immediately turn of the power 

from the main unit. Disconnect the cable from the connector on the backside or the main 

unit. Then, read this section carefully and follow the instructions. If the abnormality cannot 
be solved even after that, please contact the shop where you purchased the product (the 

agency), or the nearest service station of our company. 

 Symptom: 

•  The power cannot be supplied to the unit. (All indicators do not light up at all, and the 

fan does not turn.) 

 Contents to be confirmed: 

•  Check the DC power supply unit to confirm that the power is turned ON. If you are 

using an AC adapter, check to see if the AC plug is securely inserted into the wall 

outlet. 

•  Check the input voltage to confirm that it is within the specified range. 
•  Check the Power Signal Cable to confirm that the wire is not broken. 

• Check the Power Signal Cable to confirm that the wiring has been correctly 

performed. 

•  Check the Discharge Needle Unit is installed in the correct manner. 

 

 Symptom: 

•  The abnormality indications LED lights up. 

 Contents to be confirmed: 

•  The Discharge Needle may be soiled or damaged. Carry out the maintenance work 

for the Discharge Needle Unit in accordance with the instructions given under 

Section 7 “Maintenance.” 

• Check the Discharge Needle Unit to confirm that the unit has been securely installed. 

 

 Symptom: 

•  No static elimination is performed. 

 Contents to be confirmed: 

•  The Discharge Needle may be soiled or damaged.    Carry out the maintenance work 

for the Discharge Needle Unit or replace the unit with a new one in accordance with 

the instructions given under Section 7 “Maintenance.” 

 Symptom: 

•  The abnormal output circuit is not working. 

 Contents to be confirmed: 

•  Carry out the setting of the NO (contact a)/NC (contact b) contact selector switch 

once again in accordance with 5.1 “Setting of Contacts for Abnormal Output” in this 

manual. 

         

Caution 

The abnormal output circuits will start working about 2 seconds after the power is turned 

on. Pay special attention when designing the abnormal detection circuits when this 
product is to be built into a system. 

 

 Symptom: 

•  The Power Switch LED lights up but the High-voltage Power Supply Indicator LED 

and the Abnormal Indicator LED do not light up. 

•  The Power Switch LED lights up but the fan does not turn. 

 Contents to be confirmed: 

•  It is possible that the product is broken down.    Please contact the shop where you 

purchased the product (the agency), or the nearest service station of our company. 

  Any other abnormal condition: 

•  If any other abnormal condition than above has been observed, immediately turn 

OFF the power from the product, and please contact the

 

shop where you purchased 

the product (the agency), or the nearest service station of our company 

 
 

 

 
 

 

 
 

 

 

JUST CONSULT US 

KOGANEI CORPORATION 

 

OVERSEAS DEPARTMENT 

3-11-18 Midori-cho, Koganei-shi Tokyo 181-8533, JAPAN 

TEL: 042-383-7271    FAX:042-383-7276 

Internet Home Page URL: http://www.koganei.co.jp 

 

z

 Please understand that the appearance and the specifications of this Product may be 

altered without advance notice for improvements. 

 

Discharge 
needle unit

Discharge needle 
unit set screw

DTRY-ELW22

Discharge needle cleaning brush

Discharge needle (8 pieces)

LOW

HIGH

3

2

1

FLOW

H V

ALARM

POWER

Discharge needle cleaning brush

Discharge 
needle(8pieces)

Discharge 
needle unit

Parts to be cleaned 

Front side of the Discharge needle unit

Back side of the Discharge needle unit

Filter

Filter cover

POWER

ALARM

H V

FLOW

1

2

3

HIGH

LOW

Slits

Both ends

DTRY-ELW22

Discharge needle 
unit
Discharge needle unit 
set screw

4

3

2

1

4(Green):0V

3(Red)  :+24V

  DC

2(Black):ALARM

1(White):ALARM

Main unit Connector Number

Main
Circuit

1(White):ALARM

2(Black):ALARM

3(Red)  :+24VDC

4(Green):0V

DC Power;+24VDC

LOAD

DC24V

Internal Circuits External Circuits

MAX DC24V

50mA

Grounding Terminal

Drop-out protection washer (2 locations)

Knurl screw (2 locations)

Screwing position (2 locations)

Bracket of discharge needle unit

LOW

HIGH

3

2

1

FLOW

H V

ALARM

POWER

Discharge needle unit set screw

Discharge needle unit set screw

Ver1.03

Reviews: