SENS (Sensitivity)
Sensitivity is affected by distance conditions. In the hot outside, the sensor has difficulty in
detecting changes in heat. In cold temperatures, the sensor has easily to detecting changes
in heat.
Minimum SENS Position
Turn the dial counterclockwise to the minimum setting. Ideal for short distance conditions. If
the sensitivity is a tripping nuisance, it can be reduced by turning the knob counterclockwise
towards the minimum setting.
Maximum SENS Position
Turn the dial clockwise to the maximum setting. This is ideal for long-distance conditions. If
the sensitivity is not enough, it can be increased by turning the knob clockwise towards the
maximum setting.
Note:
Turn the dial anywhere between the minimum and maximum setting to adjust the
level of sensitivity, as needed.