Error Code Chart
Led
Reading
Cause
Solution
E0
Water temperature is lower than
zero degree or exceed 55°C
Adjust water temperature
Temperature sensor failure
Contact kogan.com for support.
E1
E1 immediately shows after
pressing FILTER or HEATING
Clean parts and tubes that water goes
through
E1 shows 15s after pressing FILTER
or HEATING
•
Add more water to the minimum
line;
•
Clean parts and tubes that water
goes through;
•
Contact kogan.com for support.
Problem
Cause
Solution
No display on
the control
panel
Power failure
Check power supply
PRCD is off
Reset PRCD by following PRCD Testing
section
PRCD broken
Contact kogan.com for support.
Spa leaking
Spa inlet/outlet connection
not securely tight
Tighten the inlet and outlet connection by
wrench
Drainage valve is not closed
completely
Close the drainage valve.
Contact kogan.com for support if spa is
still leaking.
Water leaks from the spa pool
body
Repair the leaking hole/spilt with the
repair kit material
Not heating
properly
Temperature set too low
Set a higher temperature
Heating element failed
Contact kogan.com for support.
Low water level
Add more water to reach the minimum
water line
Temperature protection switch
trip off
Reset the heater
Bubble Air
Blower Does
Not Work
Bubble motor failure
Contact kogan.com for support.
Auto-off 10 minutes
Waiting for 10 minutes and turn on the
Bubble button again
Inflation knob is in <ON>
position
Turn the knob to <OFF> position and turn
on the bubble button again.