In an emergency:
(a)
To stop the engine in an emergency, move the engine switch to the
“
off
” position.
In normal use:
(a) Turn the “
no-fuse
” breaker to the “
off
” position.
(b) Unplug all appliances.
(c) Move the engine switch to the “
off
” position.
(d) Turn the fuel valve to the “
off
“position.
Never leave an appliance plugged into the generator when you stop the
generator, as damage could result to the generator and/or
appliance.
Notice
MAINTENANCE AND STORAGE
●
Maintenance
(Please refer to the Honda Engine Manual)
Periodic inspection and adjustment of the Honda engine are essential if a high
level of performance is to be maintained. Regular maintenance will also ensure
a long service life. The required service intervals and kind of maintenance to be
performed are described in the Honda Owner’s Manual. Please refer to the
Honda Owner’s manual for more details.
●
Transportation/Storage
(Please refer to the Honda Engine Manual)
When transporting the generator, turn the fuel valve OFF and keep the engine level to
prevent fuel spillage.
When the generator is in storage for a long period, carry out the following maintenance.
Please refer to the Honda Owner’s manual.
(a)
Store generator in a well-ventilated, low humidity area.
(b)
Clean each part with an oil permeated rag.
(c)
Change the engine oil.
(d)
Clean the air cleaner.
(e)
Empty the gasoline from fuel tank and carburetor.
(f)
Pull recoil starter until resistance is felt, leaving handle in that
position.
MAN-GENef(12-99)