Be sure to ground the generator if the connected
electrical equipment is grounded.
When the generator is overloaded or a short circuit is made, the “circuit breaker”
switch will stop the engine to protect the circuit automatically. If the “circuit breaker”
switch trips during operation, the generator is either over loaded or the appliance is
defective.
Check the appliance and/or generator for overloading or defect, make necessary
corrections or repairs before use.
Dual voltage type (KD5500VR,KD5500VRS,KD7000VR,KD7000VRS) only (Diagram 4 , 5)
1. Select the voltage using the “select” switch in accordance with the electrical appliance.
Refer to table below
SWITCH
LOWER VOLTAGE RECEPTACLE
HIGHER VOLTAGE RECEPTCLE
120V
RATED OUTPUT IS AVAILABLE
UNAVAILABLE
120V/240V
HALF OF RATED OUTPUT IS
AVAILABLE
RATED OUTPUT IS AVAILABLE
2. Place generator’s “Circuit breaker” switch in the “ON” position.
3. Start engine (Please refer to the Honda Engine Owner’s Manual.)
4. Allow the engine to warm up for 2-3 minutes before connecting tools or appliances.
5. Insert the plug of the electrical appliance into the “AC receptacle”.
6. Place generator’s “Circuit breaker switch” in the “ON” position.
7. Reset the GFCI receptacle.