5.4 On board repair
5.4.1 Replacement of fuse
The location of the fuses is on the back panel of Display unit.
Fuse type and rating
Application
Type, dimension (mm)
Fuse characteristic
Rating
Main power
Tubular (φ6.4 x 30)
Normal blow
15 A
Modulator high voltage
Tubular (φ5.2 x 20)
Normal blow
0.8 A
Antenna drive motor
Tubular (φ5.2 x 20)
Normal blow
10 A
Fuse location
Figure 5.3 Fuse locations on Display unit back panel
Modulator
High voltage
Antenna
Drive motor