MDC-5200/5500 Series
Chapter 6 Maintenance
0092655002-03
6-1
Chapter 6 Maintenance
For health safety reason, transmission is basically inhibited when antenna is not rotating.
However when transmission is required for any reason without antenna rotation, following
procedure is provided to do it.
*** Special Service Mode ***
1. Turn off the radar and remove the Antenna drive motor fuse according to Fig-5.2.
2. Turn on the radar at the Operation unit by pressing the POWER ON/OFF key while the OFF key is
pressed.
Keep pressing the OFF key until "NO ERROR DETECT" is displayed.
3. After preheating time of 3 minutes, press the STBY/TX key.
If the magnetron is already heated, transmission is possible after 10 seconds, when "NO ERROR
DETECT" indication disappears.
6.1 List of parts that have longevity
Radar uses parts that have the following longevities.
List of parts that have longevity
name
type
location
Life expectancy
Magnetron
MAF1421BY
RB806
3000 to 4000H
MAF1562R
RB807
2000 to 3000H
MAF1565N
RB808
2000 to 3000H
M1568BS
RB809
1000 to 2000H
Geared motor
VGKC12-25N50L2XT6
RB808/809
5000H
23G61668
RB806/807
5000H
Motor brush
24Z125209
RB806/807
2000H
Fan
F614T-12MC
RB809
70000H
LCD Unit
LQ150X1LX9K
MRD-109
50000H (25°C)
NL10276BC24-37UC
MRD-111
70000H (25°C)
Battery
CR2032
MRD-109/111
E63-700*
For storage : 1 year
1 hour operation in every week: 8
years
To prevent electric shock, be sure to turn off the radar system power before
opening the cover of the antenna unit.
Warning:
*Subject to version change
Summary of Contents for MDC-5204
Page 1: ......
Page 2: ......
Page 26: ...Chapter 3 Installation method MDC 5200 5500 Series 3 2 0092655002 03 RB808 RB809 Unit mm inch ...
Page 70: ... This page intentionally left blank ...
Page 154: ... This page intentionally left blank ...
Page 174: ... This page intentionally left blank ...
Page 175: ...0092655002 03 A 1 INTER CONNECTION DIAGRAM RB806 ...
Page 176: ...A 2 0092655002 03 INTER CONNECTION DIAGRAM RB807 ...
Page 177: ...0092655002 03 A 3 INTER CONNECTION DIAGRAM RB808 ...
Page 178: ...A 4 0092655002 03 INTER CONNECTION DIAGRAM RB809 ...
Page 179: ...0092655002 03 A 5 INTER CONNECTION DIAGRAM MRD 109 MRO 108 ...
Page 180: ...A 6 0092655002 03 INTER CONNECTION DIAGRAM MRD 111 ...
Page 181: ......
Page 182: ......