Chapter 7 Input/output data
MDC-5000 Series
7-16
0092653004-00
7.4.2 VDR (external monitor) and Alarm output signal specification
Output connector name: VDR & Alarm
Connector used: BU-10PMMP-LC7001
Connector acceptable: BU-10BFFA-LL7001
Pin location is shown below.
Signal specification
This RGB output is compliant with the image test defined in the VDR test standard IEC61996.
VDR output cannot be deactivated by the user.
Signal name
Frequency
Polarity
Signal width Level
Impedance
Horizontal sync signal
(H-SYNC)
48.363 kHz
Negative
2.092
μs
TTL
200 Ω
Vertical sync signal
(V-SYNC)
60.0 Hz
Negative
124
μs
TTL
200 Ω
R, G, B Video signal
-
Positive
-
0.7 V p-p
75 Ω
Alarm output
-
-
Contact*
-
Capacity 1A
*
Alarm contact will close in case of failure.
7.4.2.1 Circuit for horizontal sync, vertical sync signal output
7.4.2.2 Circuit for R, G, B video signal
Pin number
Signal name
1
RVD
2
R-GND
3
GVD
4
G-GND
5
BVD
6
B-GND
7
H-SYNC
8
V-SYNC
9
ALARM
10
ALARM
RVD/GVD/BVD
GND
R, G, B Video signal
Ground
75
GND
TC74VHC08
Horizontal sync,
vertical sync signal
Ground
H-SYNC/V-SYNC
75
LMH6683
J1
External monitor and alarm output connector pin
assignment
(Processor unit upper view)
1
2
3
4
5
6
7
8
9
10
External monitor and alarm output
connector pin assignment
Summary of Contents for MDC-5004
Page 1: ......
Page 2: ......
Page 20: ...Chapter 3 installation method MDC 5000 Series 3 2 0092653004 00 RB808 RB809 Unit mm inch ...
Page 88: ... This page intentionally left blank ...
Page 114: ... This page intentionally left blank ...
Page 130: ... This page intentionally left blank ...
Page 150: ... This page intentionally left blank ...
Page 151: ...0092653004 00 A 1 INTER CONNECTION DIAGRAM RB806 ...
Page 152: ...A 2 0092653004 00 INTER CONNECTION DIAGRAM RB807 ...
Page 153: ...0092653004 00 A 3 INTER CONNECTION DIAGRAM RB808 ...
Page 154: ...A 4 0092653004 00 INTER CONNECTION DIAGRAM RB809 ...
Page 155: ...0092653004 00 A 5 INTER CONNECTION DIAGRAM MRM 110 MRO 110 ...
Page 156: ......