Chapter 6 Maintenance
MDC-5000 Series
6-4
0092653004-00
6.3 Method of exchanging the magnetron
6.3.1 Magnetron replacement (RB806)
1) Unsolder the yellow wire and green wire from the
pulse transformer terminals.
2) Pull out to wire through hole for wire, remove the
corrugated tube.
Wire through hole
Corrugated tube
Yellow wire
Green wire
Unsolder two wires
E38-120X
Pulse transformer
Summary of Contents for MDC-5004