Technical information
Page 77
6.8 Interface sentences
The IEC 61162 sentences accepted by and output by the AIS transceiver
serial data ports are listed in Table 9.
* External Display 2 / Long-range / DGNSS interfaces use the same port. Please select the
required interface in the Interface menu.
Table 9 IEC 61162 Sentences input and output
The default SSA key is ABCDZX. Please contact your dealer if you wish to
change it.
6.8.1
Legacy sentences
AIS alerts are now provided using the Bridge Alert Management requirements.
However, in order to main compatibility with legacy systems, the ALR
sentence continues to be supported. The details of the supported alerts are
shown in Table 10.
Data port
Input sentences
Output sentences
Sensor 1
Sensor 2
Sensor 3
DTM, GBS, GGA, GLL,
GNS, HDT, RMC, ROT,
THS, VBW, VTG
N/A
External
Display
External
Display 2*
Pilot
ABM, ACA, ACK, ACN,
AIR, BBM, DTM, EPV,
GBS, GGA, GLL, GNS,
HDT, RMC, ROT, SPW,
SSA, SSD, THS, VBW,
VSD, VTG
ABK, ACA, ACS,ALC,
ALF, ALR, ARC, EPV,
NAK, SSD, TRL, TXT,
VDM, VDO, VER, VSD
Long-
range*
LRF, LRI
LR1, LR2, LR3, LRF, LRI
DGNSS*
RTCM SC-104 binary
format