background image

KODAK PROFESSIONAL TRI-X 320 and 400 Films 

 F-4017

11

Characteristic Curves

KODAK PROFESSIONAL TRI-X 400 Film / 400TX, 35 mm

20°C (68°F)

Small Tank; Agitation at 30 second intervals;

6 minutes

7 minutes

9 minutes

11 minutes

3.0

1.0

Diffuse visual

KODAK PROFESSIONAL T-MAX Developer,

Process:

Densitometry:

0.0

1.0

4.0

3.0

2.0

1.0

DENSITY

2.0

0.0

4.0

LOG EXPOSURE (lux-seconds)

Characteristic Curves

KODAK PROFESSIONAL TRI-X 400 Film / 400TX, 120-size

20°C (68°F)

Small Tank; Agitation at 30 second intervals;

6 minutes

7 minutes

9 minutes

11 minutes

3.0

1.0

Diffuse visual

KODAK PROFESSIONAL T-MAX Developer,

Process:

Densitometry:

0.0

1.0

4.0

3.0

2.0

1.0

DENSITY

2.0

0.0

4.0

LOG EXPOSURE (lux-seconds)

Characteristic Curves

KODAK PROFESSIONAL TRI-X 400 Film / 400TX, 35 mm

 

 

NOTICE:

 The sensitometric curves and data in this publication represent product tested 

under the conditions of exposure and processing specified. They are representative of 
production coatings, and therefore do not apply directly to a particular box or roll of 
photographic material. They do not represent standards or specifications that must be 
met by Eastman Kodak Company. The company reserves the right to change and 
improve product characteristics at any time.

LOG EXPOSURE (lux-seconds)

4.0

0.0

2.0

DENSITY

1.0

2.0

3.0

4.0

1.0

0.0

Densitometry:

Process:

VERSAMAT 11 Film Processor,

Diffuse visual

1.0

3.0

4 FPM
5 FPM
6 FPM
7 FPM

DURAFLO RT Developer,
26.5°C (80°F)

Summary of Contents for TRI-X 320

Page 1: ...ted subjects or fast action for photographing subjects that require good depth of field and fast shutter speeds and for extending the distance range for flash pictures TRI X 400 Film 400TX is availabl...

Page 2: ...6 at 1 500 for backlit close up subjects Use f 8 at 1 500 for backlit close up subjects Subject shaded from the sun but lighted by a large area of clear sky Exposure and Development Adjustments for L...

Page 3: ...aking separation negatives For TRI X 320 sheet film only DARKROOM RECOMMENDATIONS Handle unprocessed film in total darkness Using a safelight will affect your results If absolutely necessary after dev...

Page 4: ...the first minute Then agitate once per minute by lifting the basket rack or spindle out of the developer tilting it approximately 30 degrees draining it for 5 to 10 seconds and reimmersing it Alternat...

Page 5: ...41 2 41 4 33 4 31 4 HC 110 B 51 4 43 4 41 4 4 31 2 61 4 51 2 5 41 2 4 D 76 10 9 81 4 71 2 61 2 111 2 101 4 91 2 83 4 71 2 D 76 1 1 141 4 123 4 113 4 103 4 91 4 XTOL 83 4 73 4 71 4 61 2 53 4 101 4 9 8...

Page 6: ...21 2 21 4 D 76 6 51 4 43 4 41 2 4 D 76 1 1 9 8 71 4 63 4 6 MICRODOL X 73 4 63 4 61 4 53 4 5 FINAL STEPS 65 to 75 F 18 to 24 C PUSH PROCESSING Push processing allows you to expose the film at higher fi...

Page 7: ...ent Time Minutes EI 3200 3 Stop Push Process Development Time Minutes 65 F 18 C 68 F 20 C 70 F 21 C 72 F 22 C 75 F 24 C 65 F 18 C 68 F 20 C 70 F 21 C 72 F 22 C 75 F 24 C T MAX RS 83 4 8 71 2 7 HC 110...

Page 8: ...rocessor Model 5 11 or 411 with KODAK DURAFLO RT Developer Starter KODAK DURAFLO RT Developer Replenisher and KODAK Rapid Fixer Processing Steps and Conditions for KODAK VERSAMAT Film Processors The r...

Page 9: ...n a machine speed that transfers the film every 2 minutes The times given below are starting point recommendations for T MAX RS Developer and Replenisher and XTOL Developer Make tests to determine if...

Page 10: ...RI X 320 Film 16 fine CURVES Modulation Transfer Function Spectral Sensitivity Curves Note Modulation Transfer Function and Spectral Sensitivity were generated using the older version of this film KOD...

Page 11: ...ometry 0 0 1 0 4 0 3 0 2 0 1 0 DENSITY 2 0 0 0 4 0 LOG EXPOSURE lux seconds Characteristic Curves KODAK PROFESSIONAL TRI X 400 Film 400TX 35 mm NOTICE The sensitometric curves and data in this publica...

Page 12: ...PROFESSIONAL TRI X 400 Film 400TX 120 size LOG EXPOSURE lux seconds 4 0 0 0 2 0 DENSITY 1 0 2 0 3 0 4 0 1 0 0 0 Densitometry Process KODAK PROFESSIONAL D 76 Developer Diffuse visual 1 0 3 0 12 minutes...

Page 13: ...sitometry Process Large Tank at 20 C 68 F Diffuse visual 0 8 25 D 76 T MAX RS XTOL HC 110 B MICRODOL X Characteristic Curves KODAK PROFESSIONAL TRI X 320 Film 320TXP 120 220 Contrast Index Curves KODA...

Page 14: ...Tank 20 C 68 F Process Densitometry 1 1 0 7 0 6 0 5 0 4 CONTRAST INDEX 15 10 5 0 0 3 DEVELOPMENT TIME MINUTES 20 1 0 0 9 Characteristic Curves KODAK PROFESSIONAL TRI X 320 Film 320TXP Sheets Contrast...

Page 15: ...es KODAK PROFESSIONAL TRI X 320 Film 320TXP Sheets D 76 1 1 XTOL 1 1 MICRODOL X HC 110 B XTOL T MAX RS D 76 25 0 8 Diffuse visual Rotary Tube Development at 20 C 68 F Process Densitometry 1 1 0 7 0 6...

Page 16: ...OME II RC Paper G 21 KODAK POLYCONTRAST III RC Paper G 24 KODAK POLYMAX Fine Art Paper G 26 KODAK POLYMAX II RC Paper G 27 KODAK PANALURE SELECT RC Paper G 28 KODAK P MAX Art RC Paper J 24 KODAK HC 11...

Reviews: