Kodak FL5.2 Installation Manual & Users Manual Download Page 5

2

3. Safety

Any work on the Batteries should be handled by authorized technicians and hence it is understood that

the technicians should familiarize themselves with the contents of this manual before any maintenance or

installation is carried out on the system.

3.1 Handling

·

Do not expose battery to open flame.

·

Do not place the product under direct sunlight.

·

Do not place the product near flammable materials. It may lead to fire or explosion in case of

accident.

·

Store in a cool and dry place with ample ventilation.

·

Do not store the product near water sources.

·

Store the product on a flat surface.

·

Store the product out of reach of children and animals.

·

Do not damage the unit by dropping, deforming, impacting, cutting or penetrating with a sharp

object. It may cause leakage of electrolyte or fire.

·

Do not touch any liquid spilled from the product. There is a risk of electric shock or damage to skin.

·

Always handle the battery wearing the insulated gloves.

·

Do not step on the product or place any foreign objects on it. This can result in damage.

·

Do not charge or discharge damaged battery.

·

Do not store the battery near water sources.

3.2 Installation

·

Do not connect the FL5.2 to inverter conductors or Photo-Voltaic conductors. This will damage the

battery and may result in explosion.

·

After unpacking, please check the product for damages and missing parts.

·

Make sure that the inverter and battery is completely turned off before commencing installation.

·

Do not interchange the positive and negative terminals of the battery.

·

Ensure that there is no short circuit of the terminals or with any external device.

·

Do not exceed the battery voltage rating of the inverter.

·

Do not connect the battery to any incompatible inverter.

·

Do not connect different battery types together.

·

Please ensure that all the batteries are grounded properly.

·

Do not open the battery to repair or disassemble. Only Kodak is allowed to carry out any such

repairs.

·

In case of fire, use only dry powder fire extinguisher. Liquid extinguishers should not be used.

·

Install the batteries only inside approved Kodak enclosure. Installing the battery anywhere outside

is strictly forbidden.

·

Do not install the battery near water sources or places where the battery can get wet.

·

Install the battery away from children or pets.

·

Do not use battery in high static environment where the protection device might be damaged.

·

Do not install with other batteries or cells.

3.3 Response to Emergency Situations

The battery can be used in single or multi machine in parallel. It is designed to prevent hazards or failures.

However, licensee or any of it’s partner cannot guarantee their absolute safety.

Under exposure to the internal materials of the battery the following recommendations should be carried

out by the user.

·

If there has been inhalation, please leave the contaminated area immediately and seek medical

attention.

·

If there has been contact with eyes, rinse the eyes with running water for 15 minutes and seek

medical attention immediately.

·

If there has been contact with the skin, wash the contacted area with soap thoroughly and seek

medical attention immediately.

·

If there has been ingestion, induce vomiting and seek medical attention.

Summary of Contents for FL5.2

Page 1: ...5...

Page 2: ...1...

Page 3: ...mation 4 4 1 Battery Module Specifications 4 4 2 Battery Charge discharge Curve 5 5 Product Features 6 5 1 Battery System Features 6 6 Installation 8 6 1 Items in the Package 8 6 2 Clearance 9 6 3 Too...

Page 4: ...er Installation the Installer must explain the user manual to the end user 2 Symbols Caution risk of electric shock Do not place nor install near flammable or explosive materials Install the product o...

Page 5: ...terminals of the battery Ensure that there is no short circuit of the terminals or with any external device Do not exceed the battery voltage rating of the inverter Do not connect the battery to any...

Page 6: ...other parts of the system Under any fire situation please evacuate the people from the building immediately before trying to extinguish it Water Situation The battery modules are not water resistant...

Page 7: ...100 0 5C 25 2 C Nominal voltage Vdc 51 2 Battery voltage range Vdc 43 2 57 6 Max continuous discharging current A 100 Max continuous charging current A 100 Recommended charging current CC CV A 100 Ch...

Page 8: ...level over current COC 105A Lasts 30s 60s Recover Second level over current COC2 125A Lasts 1s 60s Recover Battery discharge First level over current DOC 110A Lasts 300s 60s Recover Second level over...

Page 9: ...reverse polarity ground fault over temp in rush current Battery Protection Internal short circuit over voltage over current over temp under voltage The battery system contains the following Interface...

Page 10: ...ery to the earth for safety purposes Handle The handle is used to carry or move the battery Power Terminal A set of positive and negative terminals to connect the battery to the inverter When you are...

Page 11: ...are provided separately and are not included in the battery package Please contact your distributor or reseller for availability A B C D E F G H I J K Object Quantity Description Object Quantity Descr...

Page 12: ...ent air The battery pack is cooled by natural convection If the battery pack is entirely or partially covered or shielded it may cause the battery pack to stop operating 6 3 Tools The following tools...

Page 13: ...make sure the holes are deep enough at least 50mm for installation and then tighten the expansion tubes STEP 3 Install the expansion tubes in the holes and tighten them Then install the wall bracket b...

Page 14: ...f the battery Connect the communication network cable to the CAN interface of the battery connect the ground terminal of the battery with the ground wire and lock the nut Note Parallel multiple batter...

Page 15: ...ress selection Definition of address switch for parallel machine When the battery pack is connected with multiple batteries in parallel the address switch can be used to distinguish different pack add...

Page 16: ...7 Slave 8 Slave 9 Slave 10 Slave 11 1 0001 0000 2 0010 0000 0000 0001 3 0011 0000 0000 0001 0000 0010 4 0100 0000 0000 0001 0000 0010 0000 0011 5 0101 0000 0000 0001 0000 0010 0000 0011 0000 0100 6 0...

Page 17: ...D indication When the battery is in normal operation the alarm LED is off and after the fault occurs the alarm LED is always on SOC LED indication Status Charge Discharge Stand by 100 On On Off On On...

Page 18: ...ED2 LED3 LED4 LED5 ALARM RUN Adc afe Fault High Voltage Fault Low Voltage Fault High Temperature Low Temperature Over current Over Voltage Temperature Leakage Fault Inverter Comm Fault Parallel Comm F...

Page 19: ...e is no loose no broken no corrosion at connection point Check the installation environment such as dust water insect etc Make sure it is suitable for IP21 battery system 4 If the battery is stored fo...

Page 20: ...17 V5 1 10 203 00033 06...

Reviews: