A-61092 September 1999
5-1
5
Maintenance
Cleaning tasks
To keep your scanner in good operating condition, the following tasks
should be performed:
•
Cleaning the imaging guides (daily)
•
Cleaning the feed and separator roller (semi-automatic feeder)
(daily)
•
Cleaning the feeder module and separator roller (automatic feeder)
(daily)
•
Cleaning the paper path (daily)
•
Vacuuming inside the scanner (daily)
•
Cleaning the exposure lamp housings (weekly)
•
Cleaning the cabinet (weekly)
•
Cleaning the air filter (monthly)
For additional maintenance and feeder adjustment information, see
Kodak publication A-61604. This publication is part of the Maintenance
and Feeder Adjustment procedure video; Catalog Number 828 5306.
Cleaning materials
Materials needed to perform maintenance procedures are:
•
A mild cleaning agent
•
A quality lens cleaner
•
A soft, clean, lint-free cloth
•
A soft-bristled cleaning brush
•
A vacuum cleaner
•
Staticide
Wipes
•
Roller Cleaning Pads
•
Paper Path Cleaner
IMPORTANT:
Do not use any unauthorized commercial cleaning
solvent in any of the cleaning procedures.
Replacement parts
Consumable parts that can be replaced by the customer include:
•
Air
filter
•
Exposure
lamps
•
Imaging guides
•
Automatic Document Feeder Module
•
Automatic Document Feeder Separator Roller
Instructions on how to replace these parts are included later in this
chapter.