![Kodak Digital Science 7520 User Manual Download Page 90](http://html1.mh-extra.com/html/kodak/digital-science-7520/digital-science-7520_user-manual_1984464090.webp)
A-61140 January 2000
8-15
Table 1 illustrates how the dimensional field values are converted to a
pass/fail status and the print clarity field values are converted to letter
grades:
Table 1 — Bar Code Grades
Grade
Field
A (Pass)
B
C
D
F (Fail)
W/N
3:1 to 2:1*
3:1 to 2.2:1**
2:1 to 1:1*
2.2:1 to1:1**
NEW
0.080 to 0.010
0.009 to 0.000
Contrast
100 to 70
60 to 55
54 to 40
39 to 20
19 to 0
MOD
100 to 70
69 to 60
59 to 50
49 to 40
39 to 0
DEF
0 to 15
16 to 20
21 to 25
26 to 30
31 to 100
RMIN
0 to 49
50 to 100
*
Narrow Element Width greater than or equal to 0.020
**
Narrow Element Width less than 0.020