Checking out door side  - Don’t need to hold handset

��

Identifying visitors

1. If press          button on the monitor, screen is turned
on automatically. And, you can check out door side.

2. After checking, screen is turned off as pressing  

button again. 

3. After internal call is made, the monitoring is not availalle

for 60 sec.

1. If press call button on the door camera, the screen is turned 

on automatically. And, you can check out door side.

2. At this time, you can easily identify visitors without lifting  

handset. ( After 60sec., Monitor screen is turned off 
automatically)

��

Opening door automatically (Regardless of handset status)

��

Internal call and intercom function 

1. For this purpose, automatic AC doorlock should be first

installed on the door and then connected with video 
doorphone

2. After communication with visitor, press           button, 

and the door is automatically opened

Caution

When additional monitor and door phone are connected to the monitor.
as doorphone has no security function, the conversation between 2 monitors
can be heard from the extended doorphone without notice.

Hold on handset and press 

button on the monitor.

Then the call signal sounds from the extended monitor or
doorphone.
And if it is answered from the extended monitor or doorphone
you can communicate.
In case the handset of the extended monitor is held on, and        

button on the extended monitor is pressed, you can

communicate.
During internal communication, if the call is made from the
camera, the beep signal sounds in a sec. and the call signal
from the camera sounds.
At same time the monitor is disconnected automatically with
extended monitor or doorphone
Then if you press           button on the monitor, you can talk
with visitor

Video Doorphone Wiring Diagram

Caution for wiring   

Available video doorphone wiring with TIV O.65mm is less than 50m in length. 

Connecting wiring between monitor and door camera should not be installed near other electrical cable,
nor be horizontal.(In such case, clear picture can not be expected due to interruption by electrical noise)

Transmission    4-wired Wiring 

TIV0.5

: Max. 20m

Cable Distance  TIV0.6

: Max. 30m

TIV0.65

: Max. 50m

Coaxial cable : Max. 100m

For the dotted line  

in TIV 1.6 must be used

For the dotted line in TIV 0.65must be 

used. 

(Max. cable distance 50m)

In case of UPT cable
wiring, please refer
to the wiring and this
wiring is
recommended.
please avoid wiring
R(audio)and
W(video) in a twisted
cable.