background image

12

13

Deletion method 1 of the entire I-BUTTON KEY: Not revealed

Deletion method 2 of the entire I-BUTTON KEY: Not revealed

1. TACT SWITCH of MAIN PBA is pushed 4 times with in 2 seconds.
2. During 2 seconds, total deletion buzzer sound is transmitted and total KEY information is deleted to

be changed as the initial status.

1. Two of registered I-BUTTON KEYs are prepared.
2. After calling connected household devices, calls are connected.
3. Under calling status, two KEYs are contacted to I-BUTTON PROBE 4 times in turn during 4 seconds.
4. For 5 seconds, it is entered into mode entry status and buzzer sound is transmitted.
5. For 10 seconds, input waiting status notification buzzer sound is transmitted and within 10 seconds,

door opening button of household device connected to calling is pushed.

6. For 2 seconds, total deletion notification sound is generated and stored KEY information is deleted.

Set door opening time

1. Under waiting status, TACT SWITCH with in main PBA is pushed for 4 seconds.
2. Currently set door opening time buzzer sound is generated for 0.5 seconds.
3. Once internal PCB button is pushed one time, together with buzzer sound, door opening time is

increased per 1 second.

* Do-1 second, Re-2 seconds, Mi-3 seconds, Pa-4 seconds (Basic values), Sol-5 seconds,

La-6 seconds, Si-7 seconds, Do-8 seconds (Maximum)

I-BUTTON Registration and Deletion

First registration method of I-BUTTON KEY

Additional registration method of I-BUTTON KEY

1. Call household device connected to the common gate camera.
2. Connect call between called household device and common gate camera.
3. I-BUTTON KEY is contacted on I-BUTTON PROBE for 5 seconds.
4. As it is recognized as unregistered I-BUTTON KEY, error sound occurs 5 times consecutively.
5. For 5 seconds, mode entry status is notified in sound.

(Input waiting status notification sound is generated for 10 seconds.)

6. Door opening button is pushed on household device under calling.

(It is registered after recognizing household door opening button.)

7. Buzzer sound advising registration of I-BUTTON KEY after the registration is transmitted.

1. Registered I-BUTTON KEY is contacted to I-BUTTON PROBE for 5 seconds.
2. After generation of recognition sound of I-BUTTON KEY, common main entrance door is

opened/closed 1 time for the first time.

3. I-BUTTON KEY to register additionally after maintaining contact for 5 seconds is contacted to

I-BUTTON PROBE.

4. When I-BUTTON KEY is registered, registration sound is transmitted.

* In case additionally registering I-BUTTON KEY is contacted to I-BUTTON PROBE within 10 seconds

under the status of registration, it is registered additionally and registration sound is transmitted.
(When10 seconds elapse, completion sound becomes in a status of waiting after transmission.)

I-BUTTON Registration and Deletion

TACT SWITCH Location

Disassemble

back case of

main body

1

2

TACT SWICH is necessary to initialize the Common gate camera and to set door opening time.

TACT SWICH

Only when the power is connected to the Terminal

, TACT SWICH is available.

DC POWER

TERMINAL

Operation Explanation

1. When the visitor presses the call button for certain house on the common gate camera,

the certain house monitor gets call signal.

2. In case of pressing talk button, the conversation is available.
3. When finishing talk, press talk button once again.

Communication with house monitor

1. During conversation with household monitor, if the door open button on the monitor is pressed,

the common gate is released, in case the door opener is equiped.

2. Spec of door opener using without power supply : DC 12V / 300mA.

Common gate camera from house monitor

1. I-BUTTON KEY registered shall contact on I-BUTTON PROBE.
2. Together with transmission of opening buzzer sound of common main entrance door,

I-BUTTON LED is lit and common main entrance is opened/closed.

Common gate open using I-BUTTON KEY

Summary of Contents for KVL-C202i

Page 1: ...rough careless treatment by consumer b Breakdown cause by unauthorized repair or system modification c Breakdown caused by natural disaster or power disorder 1 Name of the product 2 Model number of th...

Page 2: ...of wall mounting type with fixing pegs keep it safely Fixing pegs may cause injury of user Clean the dust inside the product regularly Failure to clean the dust for long time may cause fire For inspec...

Page 3: ...ving equipment be sure that plug is detached from an outlet and communication cable is disconnected Damage on cables may cause fire Voltage other than prescribed rated voltage is not permitted which c...

Page 4: ...rect ray of light Center of lens Screw Main body Common gate camera Lens Screw 1 500 1 325 1 675 500 500mm 500mm Common gate camera Installation Standard height for installation Caution of camera inst...

Page 5: ...talk to the house Refer to Page 12 Adjust audio 1 2 3 4 5 6 7 8 9 10 11 12 13 14 2 4 5 6 7 1 9 10 12 14 13 11 3 8 KVL C204i KVL C204i I Button Key KVL C204i KEL 212 Name NO KVL series to KEL series w...

Page 6: ...on KEL 212 2 wire between household monitor and KEL series are non polarity Black Normal open Brown Normal close Yellow Common Yellow Common DC adaptor Normal opne Normal close DC adaptor 1 2 2 wire H...

Page 7: ...ound is generated for 10 seconds 6 Door opening button is pushed on household device under calling It is registered after recognizing household door opening button 7 Buzzer sound advising registration...

Page 8: ...se 2 House 1 1 The House 1 user is using monitoring function 2 The House 2 user presses monitoring button when the line is busy And then on the screen of House 2 turns into BLUE SCREEN and automatical...

Reviews: