background image

26

_www.kocom.com

Security Home Auto System_

27

Release of Security Mode

Press the security button now being set to turn off security 

LED (release of security mode).
(To release the security mode, the door with sensor should be
being closed.)

When security alarming sound is heard, close the door 

and press the 

security 1

or 

security 2

button, and 

concerned LED will be turned off and security mode is 
released.

Setting the Security Mode While Being Out

Just before going out, press the 

Absence

button, and Absence LED will be turned on.

.After pressing the "Absence" and 

security

button in order, user should go out from the house 
through the door with security sensor within 60 
seconds.  At this time, the door with security 
sensor should be closed. 

If the door with security sensor is opened after 60 
seconds from user

s pressing the 

Absence

and 

"security

button in order, security alarming sound

is heard after 30 seconds from the time when the 
door opens. 

Absence LED flickers for 60 seconds after user 
presses the "Absence" and "security" button. User 
should go out through the Gate within 60 
seconds (considering the time required in user

pressing the 

outdoor

and 

security

button and 

going out, standby time is set at 60 seconds). 

When returning to home and opening the door 

(security LED is turned on), user should press the 
stop/reset button within 30 seconds to release the 

security and Absence mode. At this time, the door 
with security sensor should be closed. 

If user fails to release the Absence and security 

mode within 30 seconds, alarming sound is sent to
guard for emergency call 
(the equipment recognizes that security sensor is 
working).

Releasing the Security Mode When returning Home

Setting the 

Absence

Mode and Operation in Emergencies 

Setting the Absence Mode and Operation in Emergencies 

When user goes out from the house, press the 

Absence

button 

(Absence LED is turned on). 

When emergency occurs, alarming sound is sent to guard. 

At guard, house number that sends 

emergency alarming sound appears at 
displaying LCD window with emergency 

sign. 

Stopping the Alarming Sound

While alarming sound is heard, press the 

stop

button to turn off the alarming sound. 

Pressing the "reset" button, alarming sound is turned off and not sent to guard. 

Sensor

Sensor

Absence

security

Stop

S 1, S 2

security

Absence

Absence

S 1, S 2

emergency alarming sound 

Alarming sound

Summary of Contents for KHV-446S

Page 1: ...ome Automation System KHV 446S KHV 446T KHV 446ST KHV 456S KHV 456T KHV 456ST User s Manual This manual is based on the date as shown in the right and specifications are subject to change without noti...

Page 2: ...Quality Warranty PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control...

Page 3: ...ergent directly to the product in a way of spaying etc Moving equipment be sure that the plug is detached from an outlet For equipment whose cables are connected to terminals please contact your local...

Page 4: ...requesting repair to sales agent or A S center Keeping use equipment may cause fire and electric shock Avoid direct exposure to sunlight and store equipment at the place free from dust and high temper...

Page 5: ...short circuit Be careful that signal cables should not be wired with A C wiring it may cause poor display quality Do not drop handset its damage or short circuit due to drop may make communication im...

Page 6: ...the above mentioned cases constitute the causes of product s breakdown Pay attention to these instructions when handling the product Instructions for Installation Appropriate circuit breaker should be...

Page 7: ...low GND 3 Red VOICE Camera Voice Signal 4 White VIDEO Camera Video Signal Camera KC C50 Front Door Camera KC C50 Wiring Diagram Name of Each Part Main Body KHV 446ST and 456ST as standard Functions va...

Page 8: ...HomeAutomation System_13 12_www kocom com Terminal Wiring Diagram Specifications for Pins of Terminal Overall Wiring Diagram Specifications for Pins of Main Body...

Page 9: ...is out of range from 1 250mm at the lowest to 1 550mm at the highest adjustment of lens angle alone cannot control video image you want Thus be careful to install camera according to the proper range...

Page 10: ...ED are turned on When installing monitor and front door camera avoid where direct light or back light come into Install the front door camera where rainwater cannot reach Standard height of monitor is...

Page 11: ...Then using up down key adjust the call sign volume After adjusting the call sign volume pressing end key or waiting for 5 seconds 3rd LED among the LEDs at the left bottom side of LCD is turned off a...

Page 12: ...call If the other side does not receive the call internal line LED is turned off after 30 seconds Press the internal line button on main body Within 5 seconds press the numbers of building and house t...

Page 13: ...r In case of simultaneous calls from guard and front door LEDs of guard and front door flicker the first pressed button between the two is first linked Pressing the talk button communication with guar...

Page 14: ...lawful Entry by Thief Pressing the s 1 button security mode 1 works S 1 LED is turned on When security sensor 1 detects an invasion s 1 LED flickers and alarming sound is heard at guard for notice of...

Page 15: ...60 seconds considering the time required in user s pressing the outdoor and security button and going out standby time is set at 60 seconds When returning to home and opening the door security LED is...

Page 16: ...alarming sound stop Reset Interlocked Communication with 900MHz Wireless Telephone KHV 446ST KHV 456ST Products Interlocked Communication Method A Call from Gate or Guard While Communication Using Wir...

Page 17: ...call other house only by pressing its house No 0 4 0 2 in example and button without pressing its building No Call to Guard Guard master is installed in administration office Press the outside and but...

Page 18: ...tinent security sensor Isn t the wiring for pertinent security sensor disconnected or short circuited Isn t the door where sensor is attached opened Actions Turn on the power switch Try to other hands...

Page 19: ...ween house and lobby phone is under way lobby LED flickers press guard button after finising communication with lobbyphone Communicate with guard A Call Sign from Telephone while Communication with Lo...

Page 20: ...en lobby phone and house is under way pressing the door open button at home Common gate opens automatically A visitor presses the house number to be called and house call button Lobby phone LED house...

Page 21: ...sing the 00 buttons in order is displayed and flickers for 10 seconds 10 seconds later sign changes into in displaying window Then input 4 digits of new password and press the button Displaying YES me...

Reviews: