background image

- Camera connection wire spec

6

7

Installation Location

Product Connection Diagram

Product Connection Diagram

■ Monitor installation location

∙Standard monitor installation height

is about 1,500mm where screen    
center is at eye level.
In this case, wall-hanging metal        
center (center of piping) is 1,450mm   
above ground level.                      

∙Standard installation height

■ Caution of Camera installation

∙Avoid installing camera exposed to direct ray of light (and sun). 
∙Beware backlight and darkness of visitor’s face, which makes identification difficult.
∙Avoid installing camera in places such as the following picture. 

(1) Place illuminating sky as background
(2) Place with white wall reflecting direct ray of light
(3) Place with direct ray of light

■ Camera installation location 

∙Camera installation in height Standard

camera installation height is when 

lens is about 1,400mm above the floor.
In this case, camera stack center 
(piping box) is above 1,390mm above
ground level.                      

∙Standard installation in height

■ Directly connecting cut-off power cord with power wire

1) Do not do such electric work on your own. Installing product in this way

requires reliance on electric installation man with electric work license.

2) Insulate with insulating tape while cutting off power cord and connecting with power 

wire so electric wire metal does not expose. Contact between exposed electric wires 
cause fire or electric shock accident.

3) Such electric work requires connection after interception of supplied power.

1) Remove wall-hanger bracket metal behind monitor.                
2) Install wall-hanger bracket metal on 1 type box or wall with attached Vis.                
3) Connect wiring to monitor back terminal referring to product connection diagram.
4) Hang monitor on wall-hanging metal, and fix monitor on wall- hanger bracket metal

using attached Vis.

5) Plug monitor’

s power plug into consent and check to see if the power switch is [ON] 

on the left side of monitor.

■ Monitor installation

※The above angel of view is based on the KC-MC24 camera. 

The numbers very according to the type of camera.

■ Full System Configurations

Monitor

(KCV-W354 / DW354)

Monitor

(KCV-W354 / DW354)

1. VCC
2. GND
3. AUDIO
4. VIDEO

Door phone

(KDP-602G)

Door phone

(KDP-602G)

Door Camera

(KC-MC24)

Door Camera 2

(KC-MC24)

Door Camera 1

(KC-MC24)

2 wires

4 wires

8 wires

2 wires

2 wires

2 wires

6 wires

6 wires

4 wires

DC Door Lock

External Power Input

DC Door Lock

External Power Input

AC or DC Door Lock

External Power Input

AC or DC Door Lock

External Power Input

Monitor

(KCV-W354 / DW354)

■ Name of Each Connection Port

■ Camera Connection 

※ In case of camera KC-C60,KC-MC20,KC-30, and KC-MC31,   

please refer to the manual packed together with the camera