5.  Operating Principle 

The  Kobold  Unirota  SZM  model  by-pass  level  indicator  works  on  the  basis  of  the 
intercommunicating  vessels  principle.  The  SZM  type  glass  tube  level  indicator  is 
applicable for the indication of liquid level in small and middle-sized, standing or lying round 
containers used in food, pharmaceutical and chemical industries. The level of the liquid in 
the glass tube of the appliance is the same with the level in the round containers. The level 
of the liquid can be seen through the sight glass. 

The loads occurring at the installation is absorbed by the fixing device, thus the 
glass tube is protected  against  breaking.  The  fixing  device  also  protects  the 
glass  tube  against  the mechanical  impacts  that  may  occur  following  the 
installation.  We  recommend  that  the  normal design  level  indicators  be  fitted  on 
vessels containing pure liquids, while the indicators mounted with cleaning stubs 
(a low, or low-top stub) be fitted on containers filled with contaminated liquid. 
 
 
 

6.  Mechanical Connection 

Before installation: 

• 

Remove all transportation safety locks and ensure that no packing material 
remains within the unit. 

• 

Be sure that the maximum allowable operating pressure and temperature is not 
exceeded (see Technical data). 

• 

Install the by-pass level indicator at the side of the round containers, ensure 
the instrument is under no mechanical stress/tension (install support bracing if 
necessary). 

• 

Protect the measuring tube from external damage. 

• 

Avoid pressure peaks in the measuring tube, e.g. from sudden surges or 
stoppage of flow. 

• 

If possible, immediately after making mechanical connections, check whether 
the connections are properly sealed with no evidence of leakage. 

• 

Make sure that the connections are in plain. 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SZM

Page 1: ...Operating Instructions for By pass level indicator Model SZM...

Page 2: ...echnical Information 8 11 Order Codes 9 12 Dimensions 10 13 EU Declaration of Conformance 13 14 EU Declaration of Conformance contact 14 Manufactured by Sold by Kobold Unirota Ltd Kobold Messring GmbH...

Page 3: ...ces are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accidents Whe...

Page 4: ...tallation We recommend that the normaldesign level indicators be fitted on vessels containing pure liquids while the indicators mounted with cleaning stubs a low or low top stub be fitted on container...

Page 5: ...SZM SZM K04 0522 page 5 7 Electrical Connection 7 1 Capacitive switch option Wiring diagram BN BU pnp BK...

Page 6: ...If retrofitting of contacts is desired the SZM should be ordered with a remark prepared for retrofitting of limit contact Installing of the capacitive switch Slide the switch housing up until the glas...

Page 7: ...th cleaning hole Drain the residual medium down from your appliance using the drain valve SZM x5 the cup of cleaning hole SZM x2 SZM x3 or outlet screw SZM x1 If your appliance has shut off valves tur...

Page 8: ...nection DIN flange DN 15 50 ANSI flange 2 or union nut G NPT Scale resolution engraved 1 cm printed on foil 2 mm Max pressure 10 bar Max temperature 20 C 100 C Density any no float used Max viscosity...

Page 9: ...150 lbs A7 loose flange ANSI B 16 5 1 150 lbs A8 loose flange ANSI B 16 5 1 150 lbs A9 loose flange ANSI B 16 5 2 150 lbs B4 loose flange ANSI B 16 5 300 lbs B5 loose flange ANSI B 16 5 300 lbs B6 lo...

Page 10: ...M x x 0 Gx 84 SZM x x 1 Nx SZM x x 0 Nx SZM x x 1 Ix 153 SZM x x 0 Ix 90 SZM x x 1 Mx SZM x x 0 Mx Flange DIN SZM x x 1 Fx 139 SZM x x 0 Fx 76 Flange ANSI 150 SZM x x 1 Ax 141 SZM x x 0 Ax 78 Flange A...

Page 11: ...Foil on glass tube aluminum scale Limit Contact Mounting Note Customer cannot retrofit the contacts himself If retrofitting of contactsis desired the SZM should be ordered with a remark prepared for r...

Page 12: ...SZM page 12 SZM K04 0522 Design of the Ends Top Ends Bottom Ends...

Page 13: ...h this declaration relates is in conformity with the standards noted below EN IEC 63000 2018 Technical documentation for the assessment of electrical and electronic products with respect to the restri...

Page 14: ...SZM page 14 SZM K04 0522 14 EU Declaration of Conformance contact...

Reviews: