4. Regulation 

Use 

These units, type SWK, are used for the purpose of measuring and monitoring 
liquid flow. Only clean, low-viscous and homogeneous liquids may be measured 
which do not chemically attack the materials used in the construction of these 
units. An attempt to measure high-viscous liquids may lead to considerable 
measurement errors.  
Large dirt-particles can cause the blockage of float and subsequently turn on 
error indications. Also, ferrite particles, which deposit on float (with embedded 
magnets), can generate the same effect (we recommend a magnet-filter).  
 
These units are configured in the following manner: 

  Housing made of Brass, St. Steel or PVC 

  Attached reed contact N/O with 1m PVC cable (Brass version) 

  Attached reed contact N/O with 2m PVC cable (PVC/VA version) 

  Attached and aligned pointer display (option) 

 
 
 

5. Operating 

Principle 

KOBOLD Flow Meter/Monitor of type SWK operates according to the well known 
float principle, however without making use of the generally employed extended 
measuring tube. Inside a cylindrical flow-tube a float with aperture moves in the 
direction of the flow against the recoiling force of a spring. Within the float, a pair 
of magnets is located which trigger a potential-free protective-gas reed contact 
and drives a pointer display. The reed contact is mounted on the exterior of the 
flow-housing. The springs arrangement allows the unit to be operated without 
consideration to mounting position and keeps the installation dimensions to a 
minimum. Flow monitors of type SWK generally find application where small 
volume flow needs to be measured in a fail-safe manner. 
 
 
 

Summary of Contents for SWK 1101

Page 1: ...Operating Instructions for Float Flow Meter Monitor Model SWK...

Page 2: ...onnection 6 8 Electrical Connection 6 9 Operation Configuration Adjustments 7 9 1 Adjustment of Limit Value SWK 1 7 9 2 Adjustment of Limit Value SWK 2 7 10 Maintenance 8 11 Technical Information 8 12...

Page 3: ...hen the machines fulfil the EC machine guidelines as per PED 2014 68 EU In acc with Article 4 Paragraph 3 Sound Engineering Practice of the PED 2014 68 EU no CE mark Diagram 8 Pipe Group 1 dangerous f...

Page 4: ...C cable Brass version Attached reed contact N O with 2m PVC cable PVC VA version Attached and aligned pointer display option 5 Operating Principle KOBOLD Flow Meter Monitor of type SWK operates accord...

Page 5: ...IIA IIB and IIC b In the Zone 22 Dust Ex Category 3D at non conductive dusts with a minimum igniting energy of 3 mJ c In the Zone 1 Gas Ex Cat 2G into explosion group of IIA IIB and IIC d In the Zone...

Page 6: ...If possible it should be checked after the mechanical installation whether the connection joints piping is properly sealed Attention A displacement of switching range occurs if the flow takes place f...

Page 7: ...line and let the flow medium enter slowly till the pointer display shows the desired flow value at which the rising flow should operate the switch the value for the decreasing flow lies below due to t...

Page 8: ...ainless steel 1 4310 Gaskets none Butt rings SWK x1 brass Ms 58 SWK x2 stainless steel 1 4301 SWK x13 PVC Max temperature SWK x1 SWK x2 100 C SWK 13 60 C Max pressure SWK x1 SWK x2 250 bar SWK 13 6 ba...

Page 9: ...ax load 5 107 switching operations at low load 10V 1mA 108 switching operations 12 Order Codes Example SWK 1101 Switching range L min water Connection female Flow monitors Flow meters and monitors Swi...

Page 10: ...SWK page 10 SWK K06 0618 13 Dimensions...

Page 11: ...aration relates is in conformity with the standards noted below EN 61010 1 2011 Safety requirements for electrical equipment for measurement control and laboratory use EN 60529 2014 Protection through...

Reviews: