Kobold SEN-9601 Operating Instructions Manual Download Page 3

SEN-9601

SEN-9601 K01/0613

page 3

2. Note

Please read these operating instructions before unpacking and putting the unit

into operation. Follow the instructions precisely as described herein.

The devices are only to be used, maintained and serviced by persons familiar

with these operating instructions and in accordance with local regulations applying

to Health & Safety and prevention of accidents.

When used in machines,  the measuring  unit should be used only when the

machines fulfill the EWG-machine guidelines.

3. Instrument Inspection

Instruments are inspected before shipping and sent out in perfect condition.

Should damage to a device be visible, we recommend a thorough inspection of

the delivery packaging. In case of damage, please inform your parcel service /

forwarding agent immediately, as they are responsible for damages during

transit.

Scope of delivery:

The standard delivery includes:

Pressure Sensor

model: SEN-9601

Operating Instructions

4. Regulation Use

Any  use  of  the  “Description  Instrument”,  which  exceeds the  manufacturers

specification may invalidate its warranty. Therefore, any resulting damage is not

the responsibility of the manufacturer. The user assumes all risk  for such

usage.

Caution!

The manufacturer disclaims all responsibility in case of damages

caused by the improper use of the product and by the non-respect of

the instructions reported in this manual.

- Follow carefully the specific safety rules in case of measuring oxygen

pressure, acetylene, inflammable or toxic gas or liquids.

- Disconnect the instruments only after depressurization of the system.

- The process fluids residuals in the disassembled instruments could

affect people, the environment and the system. It is highly

recommended to take proper precautions.

Summary of Contents for SEN-9601

Page 1: ...Operating Instructions for Pressure Sensor with Ceramic Sensor Element Model SEN 9601...

Page 2: ...e 3 5 General 4 6 Installation 4 7 Electrical Connection 5 8 Maintenance 6 9 Product Label 6 10 Technical Information 6 11 Dimensions 8 12 Declaration of Conformance 9 Manufactured and sold by Kobold...

Page 3: ...ding agent immediately as they are responsible for damages during transit Scope of delivery The standard delivery includes Pressure Sensor model SEN 9601 Operating Instructions 4 Regulation Use Any us...

Page 4: ...nts storage tanks refrigeration compressors vacuum pumps and general hydraulic pneumatic pressure systems 6 Installation Before installing electrical instrument safely and securely into a plant or a s...

Page 5: ...ase should always be connected to ground through the process connection thread in order to protect it from disturbances due to electromagnetic fields or electrostatic charges If it is not possible to...

Page 6: ...arity BFSL 0 5 of the range according to EN 61298 2 Non repeatability 0 1 of the range according to EN 61298 2 Output signal deviation of zero 0 5 of span typical 0 8 of span max Thermal drift Between...

Page 7: ...erence conditions described in standard EN 61298 1 with properly assembled electric connection Output signal code 4 20 mA 0 0 5 VDC 1 0 10 VDC 2 0 5 4 5 VDC ratiometric 3 1 5 VDC 4 No of wires 2 3 3 3...

Page 8: ...SEN 9601 page 8 SEN 9601 K01 0613 11 Dimensions...

Page 9: ...Sensor Elements Model SEN 9601 to which this declaration relates is in conformity with the standards noted below DIN EN 61326 Electrical equipment for measurement control and laboratory use EMC requir...

Reviews: