5.  Operating Principle 

The Kobold Unirota NZJ model by-pass level indicator works on the basis of the 
intercommunicating vessels principle. The NZJ type glass tube level indicator is 
applicable  for the indication of liquid level in small and middle-sized, standing or 
lying round containers used in food, pharmaceutical and chemical industries. The 
level of the liquid in the glass tube of the appliance is the same with the level in 
the round containers. The level of the liquid can be seen through the sight glass. 
 
The loads occurring at the installation is absorbed by the fixing device, thus the 
glass  tube  is  protected  against  breaking.  The  fixing  device  also  protects  the 
glass  tube  against  the  mechanical  impacts  that  may  occur  following  the 
installation. We recommend that the normal design level indicators be fitted on 
vessels  containing  pure  liquids,  while  the  indicators  mounted  with  cleaning 
stubs (a low, or low-top stub) be fitted on containers filled with contaminated 
liquid. 
 
 
 

6.  Mechanical Connection 

Before installation: 

• 

Remove all transportation safety locks and ensure that no packing material 
remains within the unit. 

• 

Be sure that the maximum allowable operating pressure and temperature is 
not exceeded (see Technical data). 

• 

Install the by-pass level indicator at the side of the round containers, ensure 
the instrument is under no mechanical stress/tension (install support bracing if 
necessary). 

• 

Protect the measuring tube from external damage. 

• 

Avoid pressure peaks in the measuring tube, e.g. from sudden surges or 
stoppage of flow. 

• 

If possible, immediately after making mechanical connections, check whether 
the connections are properly sealed with no evidence of leakage. 

• 

Make sure that the connections are in plain. 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for NZJ

Page 1: ...Operating Instructions for By pass level indicator Model NZJ...

Page 2: ...echnical Information 7 11 Order Codes 8 12 Dimensions 9 13 EU Declaration of Conformance 10 14 EU Declaration of Conformance contact 11 Manufactured by Sold by Kobold Unirota Ltd Kobold Messring GmbH...

Page 3: ...ersons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accidents When used in machines the measuring unit should be used...

Page 4: ...tallation We recommend that the normal design level indicators be fitted on vessels containing pure liquids while the indicators mounted with cleaning stubs a low or low top stub be fitted on containe...

Page 5: ...witch Set the switching state LED off by adjusting the potentiometer located the end of the switch Slide the switch housing down until the glass tube is full under the switch The LED must be on If not...

Page 6: ...J is virtually maintenance free If deposits form is on the inner housing or parts periodic cleaning of the unit is recommended Remove the units from the container with a suitable tool Screw the side f...

Page 7: ...y any no float used Max viscosity 50 mm s Limit contacts Type capacitive sensor without ATEX Operating Voltage UB 10 65 VDC Short circuit protection pulsing Voltage drop UD 1 8 V Operating current IL...

Page 8: ...5 PTFE G2 G N2 NPT 00 without 1D 1 1x N O 2D 1 2x N O 1S 2 1x N O 2S 2 2x N O 0 without Y customer specification Please specify the 0 and 100 level relative to the bottom and top connection level in...

Page 9: ...NZJ Model NZJ K03 0522 page 9 12 Dimensions 30 L 20 L 29 77 L 58 max min L 40 NZJ 1 2 1 1 0...

Page 10: ...h this declaration relates is in conformity with the standards noted below EN IEC 63000 2018 Technical documentation for the assessment of electrical and electronic products with respect to the restri...

Page 11: ...NZJ Model NZJ K03 0522 page 11 14 EU Declaration of Conformance contact...

Reviews: