NBK-03 to -33 ATEX
NBK-03 to -33 ATEX K10/0322
page 3
2. Note
Please read these operating instructions before unpacking and setting the unit into
operation. Follow the instructions precisely as described herein.
The instruction manuals on our website www.kobold.com are always for currently
manufactured version of our products. Due to technical changes, the instruction
manuals available online may not always correspond to the product version you
have purchased. If you need an instruction manual that corresponds to the
purchased product version, you can request it from us free of charge by email
([email protected]) in PDF format, specifying the relevant invoice number and
serial number. If you wish, the operating instructions can also be sent to you by
post in paper form against an applicable postage fee.
The devices are only to be used, maintained and serviced by persons familiar with
these operating instructions and in accordance with local regulations applying to
Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the
machines fulfil the EC-guidelines.
Classification according to Pressure Equipment Directive 2014/68/EU
NBK-03 to NBK-33
Category assignment for dangerous media (from diagram 1)
Density
[kg/dm³]
PN
[bar
]
Category
ML
[mm]
Category
ML
[mm]
Category
ML
[mm]
NBK-03
1,0
16
← Cat. II →
4711
← Cat. III →
6000
- / -
0,9/0,8/0,7/
0,6/0,54
4600
6000
- / -
NBK-06
1,0
40
1698
6000
← Cat. IV →
∞
0,9/0,8/0,7
1588
6000
∞
NBK-07
1,0
63
1060
6000
∞
0,9/0,8/0,7
950
6000
∞
NBK-10
1,0
100
577
4084
∞
0,9/0,8
467
3974
∞
NBK-31
1,0
160
≤2090
5600
0,9
≤2020
5600
0,8
≤1900
5400
NBK-32
1,0
250
≤1180
5600
0,9
≤1110
5600
0,8
≤985
5400
NBK-33
1,0
320
≤1040
5600
0,9
≤970
5500
0,8
≤830
5400
ATTENTION! If the calculated bypass length is exactly within the range limit, then the stricter test method must be used
Summary of Contents for NBK-ATEX
Page 1: ...Operating Instructions for Bypass Level Indicator Model NBK ATEX...
Page 39: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 39...
Page 40: ...NBK 03 to 33 ATEX page 40 NBK 03 to 33 ATEX K10 0322 16 Certificates 16 1 NBK EXAM...
Page 41: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 41...
Page 42: ...NBK 03 to 33 ATEX page 42 NBK 03 to 33 ATEX K10 0322...
Page 43: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 43...
Page 44: ...NBK 03 to 33 ATEX page 44 NBK 03 to 33 ATEX K10 0322...
Page 45: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 45...
Page 46: ...NBK 03 to 33 ATEX page 46 NBK 03 to 33 ATEX K10 0322...
Page 47: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 47...
Page 48: ...NBK 03 to 33 ATEX page 48 NBK 03 to 33 ATEX K10 0322 16 2 Transmitter LOM...
Page 49: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 49...
Page 50: ...NBK 03 to 33 ATEX page 50 NBK 03 to 33 ATEX K10 0322...
Page 51: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 51...
Page 52: ...NBK 03 to 33 ATEX page 52 NBK 03 to 33 ATEX K10 0322...
Page 53: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 53 16 3 Limit contact RA excerpt...
Page 54: ...NBK 03 to 33 ATEX page 54 NBK 03 to 33 ATEX K10 0322...
Page 55: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 55...
Page 56: ...NBK 03 to 33 ATEX page 56 NBK 03 to 33 ATEX K10 0322...
Page 57: ...NBK 03 to 33 ATEX NBK 03 to 33 ATEX K10 0322 page 57...