Kobold KAL-0312 EX Operating Instructions Manual Download Page 23

 

 

KAL-EX 

KAL-EX K05/0322 

 

page 23 

 

Summary of Contents for KAL-0312 EX

Page 1: ...Operating Instructions for Flow sensor model KAL Ex with Electronic Analyzer Model KAL E Ex...

Page 2: ...nt 8 8 3 Expanding the trend indicator 8 8 4 Resetting the adjustment 9 8 5 Switching point setting 9 8 6 Temperature compensation 10 9 Fault alarms 10 10 Maintenance 10 11 Brief operating instruction...

Page 3: ...devices are only to be used maintained and serviced by persons familiar with these operating instructions and in accordance with local regulations applying to Health Safety and prevention of accident...

Page 4: ...by a series of constantly illuminated LEDs on the LED strip display The currently set switching point is indicated on the LED strip display by the individually blinking LED Sensors These sensors are...

Page 5: ...he manufacturer s specifications may invalidate its warranty Therefore any resulting damage is not the responsibility of the manufacturer The user assumes all risk for such usage 5 Operating Principle...

Page 6: ...tend at least 5 mm better 5 mm into the pipe see below 6 3 Mounting position The sensors can be mounted in any position provided that the piping is completely filled with the liquid to be monitored Th...

Page 7: ...ice Connect the sensor cable to terminals 6 and 8 of the electronic analyzer Connect the supply line power supply to terminals 15 and 16 Caution The relays are shown in the rest positions The intrinsi...

Page 8: ...point pen The flow LED 6 will blink for approximately 30 seconds After this time has expired the flow LED 6 will stop blinking If the system is not functioning properly the flow LED 6 will blink cont...

Page 9: ...ic liquid being measured see above you can then set the switching point Adjust the flow rate Rotate the flow potentiometer 1 counterclockwise as far as it will go to the left hand stop The first LED i...

Page 10: ...to blink After 10 seconds they will go out If the system is not functioning properly the flow LED 6 will blink continuously In this case press the SET button 5 once again The device then switches bac...

Page 11: ...g range Turn to the right hand stop 2 Potentiometer for setting the temperature switching point SET button 5 for adjustment expanding measuring range 6 Flow LED illuminates when flow is greater than t...

Page 12: ...ints compensation at potentiometer Switching function relay is operated with flow terminal 9 10 closed LED illuminated relay is operated when temperature is exceeded LED illuminated terminal 12 13 clo...

Page 13: ...1210 G 1 2 KAL 1315 KAL 1415 KAL 1115 KAL 1215 G 3 4 KAL 1320 KAL 1420 KAL 1120 KAL 1220 G 1 KAL 1125 KAL 1225 G 11 4 KAL 1132 KAL 1232 G 11 2 KAL 1140 KAL 1240 M 12 x 1 KAL 0312 1 4 NPT KAL 5308 KAL...

Page 14: ...s flats A B C D A B C D E M 12x1 SW 19 23 43 G 1 4 SW 27 10 50 81 G 1 4 SW 19 26 43 G 1 2 SW 27 10 50 81 G 1 2 SW 27 43 58 G 3 4 SW 32 15 52 82 5 G 3 4 SW 32 43 58 G 1 SW 39 15 56 85 1 4 NPT SW 19 26...

Page 15: ...s Part 0 General Requirements EN 60079 11 2012 Explosive atmospheres Part 11 Equipment protection by intrinsic safety i Ebenfalls mit folgenden Europ ischen und nationalen Normen und technischen Vorsc...

Page 16: ...8 done at Hofheim on April 11th 2018 Name des Unterzeichners Name of signatory Name des Unterzeichners Name of signatory H Peters Gesch ftsf hrer CEO Manfred Wenzel Prokurist authorized signatory Unte...

Page 17: ...KAL EX KAL EX K05 0322 page 17 16 EC type examination certificate...

Page 18: ...KAL EX page 18 KAL EX K05 0322...

Page 19: ...KAL EX KAL EX K05 0322 page 19 17 IECEx certificate...

Page 20: ...KAL EX page 20 KAL EX K05 0322...

Page 21: ...KAL EX KAL EX K05 0322 page 21...

Page 22: ...KAL EX page 22 KAL EX K05 0322...

Page 23: ...KAL EX KAL EX K05 0322 page 23...

Reviews: