Ex- Supplement operating manual V31 

Page

 

3 of 12 

 

1.

 

General Instructions 

1.1

 

Steps prior to operation 

Prior to installation and operation, it is essential that the operator familiarizes himself with all of the 
instructions and information contained in the manual for non-explosion proof Variable Area Flow 
Meters V31 series as well as the present instructions. If any part of either manual is missing, contact 
Heinrichs Messtechnik GmbH to request a new manual. These manuals can also be downloaded 

from our website..

 

These  supplementary  Operating  Instructions  for  Hazardous  Locations  apply  to  non  explosion  proof  and  non 
electrical  versions  of  the  Variable  Area  Meters  V31  series.  These  instructions  are  supplementary  operating 
manuals for non-explosion proof versions. If you do not have a copy of the latter instructions, please request one 
from Heinrichs Messtechnik GmbH or download the instructions from our website. 
The information in this manual contain essentially only the data relevant to explosion protection

 

The technical data in the mounting and operating instructions for non-explosion proof versions still apply insofar 
as the present instructions do not replace them or exclude their application. 

1.2

 

 

Mounting, set up, start up and maintenance 

Installation, set up start up and maintenance are to be performed by a technician trained to work with explosion-
proof devices, or by a Heinrichs Messtechnik service technician 

 

Warning

 

Any maintenance or repair that safety relevant in terms of  explosion-protection is to be 
carried out by the manufacturer, an authorized Heinrichs  
 

 

Heinrichs  Messtechnik  GmbH  accepts  no  liability  for  any  loss  or  damage  of  any  kind  arising  from  improper 
operation  of  any  product,  improper  handling  or  use  of  any  replacement  part,  or  from  external  electrical  or 
mechanical effects, overvoltage or lightning. Any such improper operation, use or handling shall automatically 
invalidate the warranty for the product concerned. For consequential damages due to a.m. reasons, no liability 
will be accepted. 

In the event of a problem please contact the service center of Heinrichs Messtechnik: 
 

Phone:  

+49 221 49708-0       

Fax:      

+49 221 49708-178 

Internet:  

www.heinrichs.eu

 

Email:  

[email protected]

 

Contact our customer service department if your device needs repair or if you need assistance in diagnosing a 
problem with your device. 

Summary of Contents for Heinrichs V31

Page 1: ...able Area Flow Meter V31 Supplementary Operating Instructions for Hazardous Locations This operating manual contains important information for the operation in potentially explosive atmospheres Please read the instructions carefully and store them in a safe place for future reference ...

Page 2: ...3 BASIC TECHNICAL PRINCIPLES OF EXPLOSION PROTECTION 6 4 SAFETY INSTRUCTIONS 7 4 1 Atmospheric conditions 7 4 2 Hot surfaces 7 4 3 Electrostatic charge 7 4 3 1 Electrostatic charge of non conductive parts of the housing during cleaning 7 4 3 2 Process related charges 8 4 4 Mechanical shock resistance 8 4 5 Operation in hazardous areas caused by dust 8 4 6 Installation conditions 9 4 7 Marking 9 4 ...

Page 3: ...erating instructions for non explosion proof versions still apply insofar as the present instructions do not replace them or exclude their application 1 2 Mounting set up start up and maintenance Installation set up start up and maintenance are to be performed by a technician trained to work with explosion proof devices or by a Heinrichs Messtechnik service technician Warning Any maintenance or re...

Page 4: ...l material damage or even death Always comply to these warnings and proceed with caution Caution means that failure to take the prescribed precaution could result in material damage or destruction of the device We advice always to abide to these instructions Note means that the accompanying text contains important information about the product handling the product or about a section of the documen...

Page 5: ...1 01 Date 14th January 2021 2 2 Testing Certification The Variable Area Flow Meter V31 in the non electrical version was tested by the manufacturer under the Ex Directive 2014 34 EU according to following standards DIN EN 1127 1 2011 Explosive atmosphere basis concept and methodology and DIN EN ISO 80079 36 2016 Non electrical equipment for use in hazardous areas Part1 Principles and requirements ...

Page 6: ... category is intended for use in areas in which explosive atmospheres caused by gases vapours mists or air dust mixtures are unlikely to occur or if they do occur are likely to do so only infrequently and for a short period only The numbers in round brackets correspond to the IEC Zones Acc EN 60079 0 ff Ex Explosion proof equipment Examples of electrical types of protection General requirements EN...

Page 7: ...ng into account the existing parameters e g pressure temperature medium materials inside the tube 4 2 Hot surfaces The unit possesses no own energy sources which would lead to an increase in surface temperature Thus the maximum surface temperature is therefore dependent on the operating conditions such as fluid temperature heat radiation or with heating jacket version of the heating medium For thi...

Page 8: ...ding 4 4 Mechanical shock resistance The instruments have been type tested for impact strength in accordance with DIN EN ISO 80079 36 The devices were equipped with a polycarbonate protective cover for the glass measuring cone The requirements with impact energy of 7 Joule to metal parts and at 4 joules translucent parts were met Nevertheless we recommend that you install the Variable Area Flow Me...

Page 9: ...arking 4 7 1 Without electrical equipment In the basic version the flow meter is a non electrical equipment under intended operation without own sources of ignition and complies with the requirements of DIN EN ISO 80079 36 and can be used in hazardous areas requiring instruments of category 2 Marking Type V31 Heinrichs Messtechnik GmbH 50739 Köln II 2G Ex h IIC TX Gb II 2D Ex h IIC TX C Db Reg No ...

Page 10: ...Heinrichs Messtechnik GmbH Page 10 of 12 Ex Supplement operating manual V31 5 DECLARATION OF CONFORMITY ...

Page 11: ...Heinrichs Messtechnik GmbH Ex Supplement operating manual V31 Page 11 of 12 ...

Page 12: ...Heinrichs Messtechnik GmbH Page 12 of 12 Ex Supplement operating manual V31 ...

Reviews: