Kobold DRS-0180 Series Operating Instruction Download Page 10

DRS 

page 10 

DRS 

01/1021

 

10. Technical information

10.1.  Sensor data 

Measuring range: 

2-40 L/min water

Sensor pulse output: 

384 Hz at 40 L/min Metal Sensor
(DRS-...150; DRS-...250)
352 Hz at 40 L/min plastic sensor (DRS-...350)

Max. operating pressure: 

200 bar (DRS-...150; DRS-...250)
16 bar (DRS- ...350)

Temperature: 

-20 to +80 °C (medium, standard), -20...+150 °C
(medium, -S00x), -20 to +100 °C (storage)

Measuring accuracy: 

±1.5% of f.s.
±5 % of f.s. (DRS-0)

Linearity: 

±0.5 % of f.s.

Repeatability: 

±0.1 % of f.s.

Electrical connection: 

plug connector M12x1 1.5 m cable (DRS-0 only)
2 m cable (DRS-...F5 only)

Protection: 

IP 65 (plug connector), IP 66 (cable)

Weight (sensor and electronics) 

Sensor: 

approx. 80 g (DRS-...350)  
approx. 550 g (DRS-...150; DRS-...250) 

Electronics: 

approx. 60 g (DRS-...K..; DRS-...F..; DRS-...L3...) 
approx. 100 g (DRS-...L442) 
approx.. 450 g (DRS-…Z…) 
approx. 650 g (DRS-...C...) 

10.2.  Evaluation electronics 

DRS-0...K000 / DRS-0...S00x 

Supply: 

5...28 V

DC

 

Output pulse: 

rectangular pulse signal, open collector, NPN, 
max. 10 mA 

DRS-...F300, DRS-...F500 

Supply: 

12…28 V

DC

 

Power consumption: 

10 mA 

Pulse output: 

PNP, open collector, max. 20 mA 

Option: 

Pt 100, 2-wire 

Response time (Pt100): 

t

90

 = 100 s 

Summary of Contents for DRS-0180 Series

Page 1: ...Operating Instruction for Turbine wheel Flow Meter Model DRS...

Page 2: ...s Analog output L 6 7 5 Cable outlet with M12x1 angle plug electronic options F3x and L3x 8 7 6 Compact electronics C30R C30M C34P C34N 8 8 Commissioning 9 8 1 Frequency output 9 8 2 Analog output 9 8...

Page 3: ...roup 1 dangerous fluids 3 Instrument Inspection These devices are checked before shipping and sent out in perfect condition Should damage to a device be visible we recommend a thorough inspection of t...

Page 4: ...low rate and temperature is also available as an additional option The rotating vane is sapphire supported this ensures a high degree of linearity and long service life 6 Mechanical Connection 6 1 Ope...

Page 5: ...ing to the following connection diagram We recommend a cross sectional area of 0 25 mm for the supply line Attention A false level on plug connections may cause destruction of unit s electronics 7 2 E...

Page 6: ...Plug connection F300P F320P F340P F390P L303P L343P 1 4 3 2 5 PT100 PT100 GND Vs out PNP Cable connection F500P F520P F540P F590P brown Vs blue GND black Signal white PT100 2 wire grey PT100 2 wire 7...

Page 7: ...DRS DRS 01 1021 Page 7 2 conductor L342 1 2 3 4 S S n c n c Vs GND 2 conductor DIN plug DRS L442 Vs GND 1 2 3 S S PE n c...

Page 8: ...ns F3x and L3x When using a pre assembled M12x1 connection cable with angled plug the cable outlet is always aligned opposite to the flow direction 7 6 Compact electronics C30R C30M C34P C34N Please s...

Page 9: ...ee Operating Instruction Manual for compact electronics with frequency output 9 Maintenance As long as the medium to be measured is not polluted the measuring unit is maintenance free In order to avoi...

Page 10: ...bility 0 1 of f s Electrical connection plug connector M12x1 1 5 m cable DRS 0 only 2 m cable DRS F5 only Protection IP 65 plug connector IP 66 cable Weight sensor and electronics Sensor approx 80 g D...

Page 11: ...LED 0 4 20 mA adjustable max 500 1 semiconductor PNP or NPN factory set N C N O contact frequency programmable with 2 buttons 24 VDC 20 3 wire approx 100 mA mA DRS F390 Supply Power consumption Pulse...

Page 12: ...34P1 Compact Electronics 4 20 mA 1 PNP Switch P Pt 100 3 wire RTD only for output options F300 F500 or L343 Stainless Steel DRS 9280 N5 3 4 NPT Male G4 G 1 2 Male Female G5 G 3 4 Male PPO Plastic DRS...

Page 13: ...tput Type Brass DRS 0180 N5 3 4 NPT Male G4 G 1 2 Male Female G5 G 3 4 Male K0000 NPN Frequency Output 5 ft PUR Cable Black without CE S0000 1 5 m Silicone Cable NPN OEM without CE Max 300 F not for D...

Page 14: ...emale female male male and female male with the same outer dimensions 35 80 SW 32 M12x1 36 50 63 4 16 D D Kabel version DRS F L OBOLD 50 44 5 1 0 2 5 1 1 8 5 2 3 7 A 1 A 1 SW 36 SW 32 80 13 5 D D Cabl...

Page 15: ...tibility EMC Part 6 2 Generic standards Immunity for industrial environments EN 61010 1 2020 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requ...

Page 16: ...ial environments BS EN 61010 1 2010 A1 2019 Safety requirements for electrical equipment for measurement control and laboratory use General requirements BS EN 60529 1992 A2 2013 Degrees of protection...

Reviews: